Charging Test Result
in conclusion
Description
The charging
system is normal
The system shows that the generator output is normal
With output
voltage
Generator output detected.
Check the belt to ensure that the generator rotates with the
engine running. Replace the broken or slipped belt and retest.
Check all connections on the generator. Especially the connector
connected to the battery. If the connector is loose or severely
corroded, clean or replace the wire and retest.
If the belt and joint are in good condition, replace the
generator. (An external voltage regulator for old vehicles may
only need to be replaced.)
Low output
voltage
The generator does not provide enough current to load the circuit
of the system, also it does not have enough current to charge the
battery.
Check the belt to ensure that the generator drives the engine to
Loaded 14.44V
Unloaded 14.0V
Ripple 153mV
CHARGING NORMAL