KW710
Cranking Test Result
The cranking voltage is normal and the battery is fully charged.
The cranking voltage is lower than the normal value, and the
starter malfunction is diagnosed.
The battery must be
charged
The battery state of charge is too low for the starter test. The
battery must be fully charged before starting the system test.
Re-test after charging the battery.
The battery must be
replaced
Before starting the cranking system test, the battery must be
replaced.
It is detected that the vehicle cannot be started.
Charging Test
Once the cranking system test is completed, the screen will alternately
display the cranking system test results and prompts. Press the Enter key to
test the charging system. Press the Enter key to perform charging test.
Follow the instructions on the screen: Increase RPM to 2500 r/min and keep
it 5 seconds, Press ENTER to continue
1. Increase the throttle when closing the load
2. The engine speed is detected and the engine is idling
3. Test the generator when the load is off and idling
4. Turn on the headlights and blower when the engine is idling
5. Test the generator when the load is clocked in and idling
6. Increase the throttle when opening the load
After the process is over, the tester displays the test results of the charging
system