③ Press the discharge lever for continuous operation of SOLENOID and the motor. Keep
'ON' state.
F3 (Automatic ice discharge function)
① When ICE, WATER & ICE button is selected, ice is automatically supplied for the
set time.
② Automatic operation is not possible when OFF is set. (Manual operation)
③ Automatic discharge is performed for the set time of At01 ~ 99.
F4 (Initial water subtraction function)
① Operates first when "ICE MAKING" switch is operated.
② FND 1
st
, 2
nd
digits (drain time) 30 seconds (oF ~ 99 seconds, Set Unit of one
second)
③ Water supply operation after drainage to high water level.
④ FND 3
rd
, 4
th
digits (number of repetitions) Standard: 3 times (1 ~ 9 times)
F5 (Automatic drain function)
① Operates when "ICE MAKING" switch is operated.
② FND 1
st
, 2
nd
digits (drain time): 2 seconds (oF ~ 9 seconds, Set Unit of one
second)
③ FND 3
rd
, 4
th
digits (drain interval): 1.0 hour (0.5 ~ 9.5 hours, every 30 minutes)
F6 (ICE + WATER volume control)
① 1
st
, 2
nd
digits Ice time Default
5 seconds (up to 99 seconds)
② 3
rd
, 4
th
digits Water time Default 5
seconds (up to 99 seconds)
F7 (UV LAMP time adjustment)
① 1
st
, 2
nd
digit lighting time Default 3 minutes (99 minutes possible)
② 3
rd
, 4
th
digits off time Default 1 hour (9 hours available)
F8 (Notify service period setting)
① A.1.0 After using 10,000 hours, the corresponding mode LED blinks for 5 seconds (for
the first 5 seconds during ice making)
② A.1.1 After using 11,000 hours, all LEDs blink for 5 seconds (1 hour cycle)
F. 9 (Cumulative uptime)
① The FND display is displayed in year, month, day, and hour, and is displayed in order
from right to left.
② Cumulative operation time of product is expressed in hour units.
③ Calculation example: 12 months for 1 year, 30 days for 1 month, 24 hours for 1 day.
※ Setting value reset function
- Pressing three buttons of UP, DOWN, and
SET for 3 seconds at the same time will set all
setting values to default values
13
F10 Change temperature display (Celcius or Farenheit)
Function of setting the unit of temperature in degrees Celsius or Fahrenheit F11
Evaporation inlet temperature display
F12
Evaporation outlet temperature display