Loading...
Every
year
Water supply
valve and Drain
valve
1. Close the shutoff valve to shut off the water supply line and
drain the water.
2. Clean the inlet of the water supply valve and check the water
supply valve and drain valve for leakage and operation.
Water hose
1. Check the water hose and clean if necessary.
Condenser (air-
cooled)
1. Inspect for cleaning. If necessary, clean with a brush or
vacuum cleaner
2. If the dust adhesion is severe, spray cleaning agent, clean
the dust, spray it with clean water, rinse and dry with air
gun.
Ice maker
1. Inspect for oil marks, loose components, tightening parts and
wires.
Upper bearing
(Ice exit head)
1. Check that 0.5mm round bar,pin gauge (or clearance
gauge) is inserted into auger and bearing clearance, and replace
all upper and lower bearings (ice exit head and lower housing)
Mechanical seal
1. Check for leaks in the bottom housing, and if there is a leak,
disassemble the auger to replace the mechanical seal.(Water
with a lot of calcium will shorten the life of replacement
parts.)
Every
three
years
Upper and lower
bearings,
Housing O-ring,
Mechanical seals,
Evaporator
cylinder, Auger
1. Please check. If the auger and bearing clearance exceeds the
factory recommended value (0.5mm or less), replace both the
upper and lower bearings.
If the contact surface of the mechanical seal is worn, cracked, or
scratched, replace it.
17