5
LOCATION REQUIREMENTS
LOCATION:
NEVER install in a “Fire wall”, “Fire barrier” or “Fire partition”.
Appliance is for indoor use only. Never vent into a laundry closet or similar room which traps
warm air. Unit must vent to an adjacent interior, ventilated space close to the ceiling. Exhaust air
must not be obstructed in any way.
Consider from the beginning that the cooling unit will be installed through the wall, close to the
ceiling of your room and MUST vent the warm air into an adjacent, air-conditioned fairly large
interior space. Do not even think of venting to the garage, or using any ducting for the air
streams. The airflow has to be totally unobstructed, keep in mind that up to 200 cubic feet of air
will be vented every minute.
To ensure proper ventilation for your KoolR, allow for sufficient space on each side and top.
Do not block free air flow on the sides, under or facing the cold side in your cellar either.
NOTE: It is important that you do not install the KoolR near an oven, radiator, or other heat
source. Do not install in a location where the temperature will fall below 55°F (13°C).