The power doesn't supply to the meter.
→Please make sure the wiring is
connected.
The wiring and fuse are not broken.
→The battery is broken or the battery is
too old to supply enough power
(DC 8 V) to make the meter work.
make sure the voltage is over DC 8 V.
Make sure the speed sensor is
connected properly.
Please check if speed sensor is
connected and working properly. Also
check whether the cable of speed sensor
has broken or lose or not.
Check the tire-size setting.
Refer to the manual 4-1 circumference
and sensing point setting.
The following situation do not indicate malfunction of the meter.Please check the following before taking it in for repair.
The meter doesn't work when
the power is on.
Th
e meter shows wrong
information.
Speed does not appear or
appear incorrectly.
Check the voltage of your battery,and
Fuel gauge does not appear
or appear incorrectly.
The odometer and trip meter
is not accumulated or
accumulated wrong data.
Check your fuel tank.
Check the wiring harness.
Is the wire connected properly.
Check the tire-size setting.
→Refer to the manual 4-3 fuel gauge
resistance setting.
It is possible that the permanent power
Tachometer does not appear
or appear incorrectly
● Please check the RPM sensor wiring is
connected correctly.
● Please check the spark plug is R type or
not. If not, please replace the spark plug
with the R type spark plug.
● Please check your setting.
 →Please refer to the manual 4-2 RPM
pulse setting.
wire is not connected well.
→Please check the red positive wire is
connect well or not.
* If the problem is not resolved after following the steps shown above, please contact your loval distributor for assistance.
● It is possible that the permanent power
wire is not connected properly.
→Check if the red positive wire is
connect propery.
The odometer and trip meter
are not accumulated or
accumulated the wrong data.
Check itemTrouble Check itemTrouble
●ExampleCurrent internal ODO is
50,000 km.
●Press the Select button three seconds
to go back to ODO screen.
●The main screen.
Setting range
99999.9 km (mlie).
User unable to adjust and
clearinternal ODO.
NOTE
4-9
Internal ODO
5
Trouble shooting
wh041ba02a(P6-6)

Other manuals for Koso DB-01

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Koso DB-01 and is the answer not in the manual?

Koso DB-01 Specifications

General IconGeneral
BrandKoso
ModelDB-01
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals