Maintenance
Co-operation with other appliances
Unit is equipped with the BLOK and NA clamps.
BLOK - relay input that switches off the slave appliance, the circuit that is connected
to the BLOK clamps (max. 0,1A 250V-) will be opened at the time of heating operation
starts up.
NA - input that locks the unit operation, opened NA contacts locks the heating operation
- co-operation with the master appliance.
Wire (2 x 0,5mm
2
) for BLOCK and NA clamps should be run inside the unit on the right
side.
The wire connections must be performed by a qualied person.
Filter cleaning:
1. Cut off power and cold water supplies.
2. Take off the unit’s cover.
3. Undo the inlet tting - on the cold water side.
4. Take the lter out from the inlet tting.
5. Clean up the lter.
6. Fix the lter back, put the gasket and do up the inlet
tting.
7. Open the cut-off valve on cold water supply pipe - check
connections for leaks.
8. Fix the unit’s cover back.
9. Vent the water system - see Venting section.