Operating
The unit switches on automatically right after
reaching appropriate rate of ow. When the
rate of ow rises the second step switches
on. A user may set the heater on work at
lower temperature range by turning the
knob in position I (economic mode - reduced
maximum power). Turning the knob in posi-
tion II sets the heater at work at higher tem-
perature range (full power mode: maximum
power = rated power).
There are two indicators on the case:
green - power supply “on”,
red - heating “on”.
Maintenance
Filter cleaning:
1. Cut off power and cold water sup-
plies.
2. Take off the unit’s cover
3. Undo the inlet tting from the orice - on
the cold water side (hold the orice with
spanner 22).
4. Take the lter out from orice.
5. Clean up the lter.
6. Fix the lter back.
7. Do up the inlet tting to the orice.
8. Open the cut-off valve on cold water
supply pipe - check connections for
leaks.
9. Fix the unit’s cover back.
10. Vent the water system see Venting
on page 8
PPH2, KDH2
KDH
GB