HUSSONG MANUFACTURING CO., INC.
INSTALLATION AND
OPERATION MANUAL
ͷ Do not store or use gasoline or other
ammable vapors and liquids in the vicinity
of this or any other appliance.
ͷ WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier from
a neighbors phone. Follow the gas
suppliers instructions.
If you cannot reach your gas supplier,
call the re department.
ͷ Installation and service must be performed
by a qualied installer, service agency or
the gas supplier.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
This appliance may be installed in
an aftermarket, permanently located,
manufactured home (USA only) or mobile
home, where not prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certied kit is used.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
English and French installation manuals are available through your
local dealer. Visit our website www.kozyheat.com.
Les manuels d’installation en français et en anglais sont disponibles
chez votre détaillant local. Visitez
www.kozyheat.com
.
DANGER
HOT GLASS WILL
CAUSE BURNS
DO NOT TOUCH GLASS
UNTIL COOLED
NEVER ALLOW CHILDREN
TO TOUCH GLASS
A barrier designed to reduce the risk of burns
from the hot viewing glass is provided with this
appliance and shall be installed for the protection
of children and other at-risk individuals.
Hussong Mfg. Co., Inc. • RVT-29-BW Report No: 0216GN057S • Rev. 2, July 2018
ROOSEVELT 29 BW
Model #RVT-29-BW
Direct Vent Gas Fireplace Insert

Table of Contents

Questions and Answers

  • A
    Anna Garrison DDSAug 8, 2025
    What to do if the main burner flame will not light on my Kozy Heat Indoor Fireplace?
    • B
      Briana EllisAug 8, 2025
      If the main burner flame on your Kozy Heat Indoor Fireplace won't light, there are several things to check: * Ensure the ON/OFF rocker switch is in the ON position. * Verify the gas supply is turned on and check for multiple shut-offs in the supply line. * Consult with a plumber or gas supplier if the gas supply is low, and check/refill the propane tank if necessary. * Check for faulty or incorrect wiring. * Remove any blockage from the plugged main burner orifice. * Ensure the pilot flame is properly directed to ignite the burner. Refer to pilot flame troubleshooting. * Replace the batteries in the remote control. * Verify the remote control is powered ON and thermostat operation is turned OFF, ensuring there's a call for heat.
  • N
    norrismichaelAug 12, 2025
    How to fix a pilot light that will not light on my Kozy Heat Indoor Fireplace?
    • P
      piercealyssaAug 12, 2025
      If the pilot light on your Kozy Heat Indoor Fireplace won't light, consider the following: * Ensure electrical power to the appliance is restored or use a battery back-up. * If using a battery back-up, ensure the batteries are fully charged. Check all wiring connections are secure and correct using the wiring schematic. * Check remote shut-off valves from the appliance to ensure the gas supply is turned on. There may be more than one valve between the appliance and the main gas line.
  • H
    holtstephanieAug 16, 2025
    Why does the pilot light keep going out on my Kozy Heat Indoor Fireplace?
    • K
      Karen MccormickAug 16, 2025
      If the pilot light on your Kozy Heat Indoor Fireplace won't stay lit, here's what to check: * Make sure there is propane in the tank and refill if necessary. * Low gas pressure can be the issue, so consult a plumber or gas supplier. This can be due to a bent line, too narrow diameter of pipe, or a low line pressure. * Verify the pilot flame envelopes the top of the flame sensor and extends far enough onto the burner for ignition. Adjust the pilot flame by turning the pilot adjustment screw on the gas valve clockwise to decrease the flame, and counterclockwise to increase it. * Ensure the pilot adjustment screw is sealed, but do not over-tighten.
  • C
    Carlos CunninghamAug 21, 2025
    What to do if the pilot and burner extinguish while in operation in my Kozy Heat Indoor Fireplace?
    • M
      Melanie GuerreroAug 21, 2025
      If the pilot and burner extinguish during operation of your Kozy Heat Indoor Fireplace, consider these potential causes: * Check the propane tank and refill if necessary. * Refer to section 9.1 Glass Assembly on page 21 for correct glass assembly installation. * Adjust the vent cap if it is incorrectly installed. * Remove any debris blocking the vent cap. * Ensure a ¼ in. (6 mm) rise per foot (30 cm) on horizontal venting. * Check for exhaust vent pipe leaks and repair if necessary. * A restrictor may need to be installed or modified if there is excessive draft.
  • T
    Troy BlackburnAug 26, 2025
    Why is my Kozy Heat Indoor Fireplace not reacting to the remote control?
    • P
      Preston RamirezAug 26, 2025
      If your Kozy Heat Indoor Fireplace isn't responding to commands, try these solutions: * Replace the batteries in the battery back or remote control. * Reprogram the remote control to the IFC module. * Reset the IFC module if a maximum number of failed ignitions or flame restorations has been reached.
  • A
    Anthony Chen PhDAug 29, 2025
    Why does the flame burn blue and lift off the burner on my Kozy Heat Indoor Fireplace?
    • A
      Arthur RodriguezAug 29, 2025
      If the flame on your Kozy Heat Indoor Fireplace burns blue and lifts off the burner, consider the following: * The venturi air shutter may need to be opened slightly to allow more air into the gas mix. Refer to section 12.2.1 Burner Venturi on page 33. * Adjust the vent cap if it is incorrectly installed. * Check the vent pipes for leaks and the vent cap for debris. Repair the vent pipes or remove debris from the vent cap, if necessary.
  • M
    mcconnelljennySep 3, 2025
    Why is the pilot flame always on and will not extinguish on my Kozy Heat Indoor Fireplace?
    • T
      Thomas BrownSep 3, 2025
      If the pilot flame is always on and will not extinguish on your Kozy Heat Indoor Fireplace, set the control system to IPI mode. The control system might be set to CPI mode.

kozy heat ROOSEVELT 29 BW Specifications

General IconGeneral
ModelRoosevelt 29 BW
CategoryIndoor Fireplace
Fuel TypeNatural Gas or Propane
VentingDirect Vent
FinishBlack
TypeGas Fireplace