HUSSONG MANUFACTURING CO., INC.
INSTALLATION AND
OPERATION MANUAL
ͷ Do not store or use gasoline or other
ammable vapors and liquids in the vicinity
of this or any other appliance.
ͷ WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier from
a neighbors phone. Follow the gas
suppliers instructions.
If you cannot reach your gas supplier,
call the re department.
ͷ Installation and service must be performed
by a qualied installer, service agency or
the gas supplier.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
This appliance may be installed in
an aftermarket, permanently located,
manufactured home (USA only) or mobile
home, where not prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certied kit is used.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
English and French installation manuals are available through your
local dealer. Visit our website www.kozyheat.com.
Les manuels d’installation en français et en anglais sont disponibles
chez votre détaillant local. Visitez
www.kozyheat.com
.
DANGER
HOT GLASS WILL
CAUSE BURNS
DO NOT TOUCH GLASS
UNTIL COOLED
NEVER ALLOW CHILDREN
TO TOUCH GLASS
A barrier designed to reduce the risk of burns
from the hot viewing glass is provided with this
appliance and shall be installed for the protection
of children and other at-risk individuals.
SP-34-LE
SP-34-MV
Models #SP-34-LE & #SP-34-MV
Direct Vent Gas Fireplaces
Hussong Mfg. Co., Inc.
SP-34-LE & SP-34-MV Report No: 19-553
Rev. 5, January 2020
Starting Serial Number: 20 83450 12

Table of Contents

Questions and Answers

  • A
    Amber FlemingAug 18, 2025
    How to fix a pilot that will not light on my Kozy Heat Indoor Fireplace?
    • M
      Monica CruzAug 19, 2025
      To resolve a Kozy Heat Indoor Fireplace pilot light that won't ignite, first, ensure that the appliance has electrical power or that the battery backup is working. Next, check all wiring connections using the wiring schematic in the manual to make sure they are secure and correct. Finally, verify that the gas supply is turned on by checking any remote shut-off valves near the main gas line, as there may be more than one valve.
  • K
    Kathleen ParkerAug 20, 2025
    What to do if main burner flame will not light on kozy heat SP-34-LE?
    • M
      Melissa JohnsonAug 21, 2025
      If the main burner flame on your Kozy Heat Indoor Fireplace won't light, begin by ensuring the ON/OFF rocker switch is in the ON position. Then, check the gas supply to confirm it is turned on and not low, consulting a plumber or gas supplier if needed, and checking/refilling the propane tank if applicable. Inspect the wiring for disconnections or improper connections. Clear any blockages from the main burner orifice. Finally, make sure the pilot flame is correctly directed to ignite the burner, referring to the pilot flame troubleshooting if necessary.
  • A
    Ashley BeasleyAug 23, 2025
    What to do if pilot light will not stay lit on Kozy Heat Indoor Fireplace?
    • K
      Kylie CohenAug 23, 2025
      If the pilot light on your Kozy Heat Indoor Fireplace won't stay lit, start by checking the propane tank and refilling it if necessary. Next, consult a plumber or gas supplier to address potential low gas pressure issues, such as a bent line or narrow pipe. Ensure the pilot flame makes proper contact with the flame rectification sensor. Finally, seal the pilot adjustment screw, being careful not to over-tighten it.
  • B
    Blake TranAug 26, 2025
    Why do pilot and burner extinguish while in operation on my kozy heat SP-34-LE Indoor Fireplace?
    • J
      Jamie PetersonAug 26, 2025
      If your Kozy Heat Indoor Fireplace pilot and burner extinguish during operation, first, check and refill the propane tank if needed. Ensure correct installation of the glass assembly. Check and adjust the vent cap installation if necessary, and remove any vent cap blockages. Verify the horizontal venting has a ¼” (6mm) rise per foot (30cm). Check for exhaust vent pipe leaks and repair if needed. Finally, address excessive draft by installing or modifying a restrictor plate.
  • L
    lisacervantesAug 27, 2025
    What to do if burner will not light on kozy heat SP-34-LE Indoor Fireplace?
    • H
      Hannah OliverAug 28, 2025
      If the burner of your Kozy Heat Indoor Fireplace won't light, first, make sure you've followed the lighting instructions: turn the gas control knob to the ON position, switch the ON/OFF rocker switch to ON, and set the wall switch, remote control, or thermostat to the heat demand position. Clear any blockages from the main burner orifice. If these steps don't work, check the remote, thermostat, or wall switch wires for proper connection and test the switch. If the burner lights with jumper wires, replace the defective switch, thermostat, or remote batteries. If the switching device checks out, use jumper wires across switches on the gas valve; if the burner then lights, the switching wires are faulty and should be replaced.
  • T
    Tonya CantrellAug 30, 2025
    Why does soot appear on the glass of my kozy heat SP-34-LE Indoor Fireplace?
    • L
      Lori WrightAug 30, 2025
      If soot appears on the glass of your Kozy Heat Indoor Fireplace, make sure the logs are placed correctly. Also, the venturi air shutter may need to be opened slightly to allow more air into the gas mix. Check and adjust the vent cap installation if necessary. Finally, remove any debris blocking the vent cap.
  • M
    Miguel RasmussenSep 1, 2025
    Why flame burns blue and lifts off burner on my kozy heat SP-34-LE Indoor Fireplace?
    • S
      Stacy SheltonSep 1, 2025
      If your Kozy Heat Indoor Fireplace's flame burns blue and lifts off the burner, the venturi air shutter may need adjustment to allow more air into the gas mix. Also, check the vent cap installation to make sure it is correct. Inspect the vent system for blockages or leaks, and repair or clear as necessary.
  • R
    Robert HollowaySep 3, 2025
    What to do if pilot will not stay lit after carefully following lighting instructions on kozy heat SP-34-LE Indoor Fireplace?
    • T
      Tiffany PayneSep 4, 2025
      If the pilot of your Kozy Heat Indoor Fireplace will not stay lit even after carefully following the lighting instructions, start by cleaning the pilot hood. Then, ensure the thermocouple connection at the gas valve is fully inserted and tight (hand tight plus 1/4 turn). If the thermocouple reading is below 15 millivolts, disconnect it and test it with a millivolt meter while starting the pilot; replace the thermocouple if the reading remains low. Adjust the pilot flame to envelope the thermopile, if necessary. Check and tighten the thermopile connections to the gas control valve. Finally, measure millivolt production with a millivolt meter; if the reading is less than 350 millivolts, replace the thermopile.
  • N
    Nancy RomeroSep 6, 2025
    What to do if burner will not stay lit on Kozy Heat Indoor Fireplace?
    • K
      Kimberly RobertsonSep 6, 2025
      If your Kozy Heat Indoor Fireplace burner won't stay lit, make sure the thermopile wires are tightened at the valve terminals. Check for and free any pinched thermopile wires. If installed, ensure the refractory panels are tight against the firebox walls, securing them with high-temperature sealant if necessary, especially around the intake duct.
  • O
    ocamposSep 8, 2025
    Why does flame burn blue and lifts off burner on Kozy Heat Indoor Fireplace?
    • G
      Gregory TaylorSep 8, 2025
      If the flame on your Kozy Heat Indoor Fireplace burns blue and lifts off the burner, the venturi air shutter may need to be opened slightly to allow more air into the gas mix. Also, check the vent cap installation to ensure it's correct. Check the vent pipe for leaks, and the vent cap for debris. Repair the vent pipe or remove debris from vent cap if necessary.

Summary

1.0 INTRODUCTION

1.1 Appliance Certification

Describes testing and standards for the fireplace appliance.

1.2 California Proposition 65 Warning

Lists chemical exposure warnings related to the product.

1.3 Requirements for the Commonwealth of Massachusetts

Details specific local installation requirements for Massachusetts.

2.0 SPECIFICATIONS

2.1 Heating Specifications

Provides BTU ratings, pressures, and orifice sizes for Natural Gas and Propane.

2.2 Electrical Specifications

Lists voltage, frequency, and amperage requirements for the appliance.

2.3 Appliance Dimensions

2.4 Safety Barrier Dimensions

3.0 FRAMING

3.1 Appliance Placement Considerations

Discusses location, heat, and placement relative to studs.

3.2 Floor Support and Protection

Details requirements for floor support and protection.

3.3 Stand-off Assembly and Installation

3.4 Nailing Tabs Installation

3.5 Clearances to Combustibles

3.6 Wall Enclosure Rough Opening

3.6.1 TV Recess Construction

Specific instructions for recessing a TV above the fireplace.

3.7 Vent Termination Framing

3.7.1 Vertical Terminations

Requirements for vertical vent pipe clearances.

3.7.2 Horizontal Terminations

Requirements for horizontal vent pipe clearances and rise.

3.8 Outdoor Covered Fireplace Installation

3.8.1 Safety Screen Barriers

Recommendations for safety barriers in outdoor installations.

3.8.2 Requirements

Specifies operating temperature and electrical requirements.

4.0 FACING AND FINISHING

4.1 Facing and Finishing Requirements

Details mantel and sidewall requirements.

4.2 Safety Barrier Installation

4.2.1 Safety Barrier Screen (#SP34-SCR)

Steps for installing the screen barrier.

4.2.2 Overlay Designs (#SP34-POL & #SP34 A-POL)

Steps for installing overlay designs.

5.0 GAS LINE CONNECTION

5.1 Gas Conversion (sold separately)

Notes on converting fuel type.

5.2 Gas Pressures

Specifies inlet and manifold pressure requirements.

5.3 Gas Line Installation

Guidelines for installing the gas line.

6.0 TERMINATION LOCATIONS

6.1 Vertical Vent Cap Termination

Details on vertical vent cap placement and clearances.

6.2 Minimum Termination Clearances

7.0 VENTING

7.1 Approved Vent Systems

Lists approved vent pipe types and manufacturers.

7.2 Venting Requirements

General requirements for combustion and ventilation air.

7.3 Use of Elbows

Guidelines on the number and type of elbows allowed.

7.4 Restrictor Plate Assembly and Installation

Instructions for installing a restrictor plate.

7.5 Vent Installation

7.5.1 Vertical Terminations

Details minimum and maximum vertical venting lengths.

7.5.2 Combination Venting

7.6 Class A Chimney;Masonry Chimney Conversion

7.6.1 4 Flex Pipe Venting Configurations

Details on flex pipe configurations for conversions.

7.7 Coaxial to Co-Linear Chimney Conversion

7.7.1 Coaxial to Co-Linear Venting Configurations

Details on specific coaxial to co-linear configurations.

7.8 #700-2 Series Direct Vent Termination Kit(s)

7.8.1 Assembly and Installation

Step-by-step guide for kit assembly and installation.

7.8.2 #700-WPT3 Installation Instructions

7.9 Vent Heat Shield Assembly Installation

7.9.1 Vertical Vent Heat Shield Installation

Steps for vertical vent heat shield installation.

7.9.2 Minimum Horizontal Venting

Steps for horizontal vent heat shield installation.

8.0 FIREPLACE SETUP

8.1 Glass Frame Assembly

Instructions for removing and installing the glass frame.

8.2 #SP34-50 A Log Set Installation

8.3 Control Board Removal and Installation

8.3.1 Control Board Removal

Steps to remove the control board.

8.3.2 Control Board Installation

Steps to install the control board.

9.0 ELECTRICAL INFORMATION

9.1 Electrical Specifications

Details electrical ratings and grounding requirements.

9.2 Wiring Requirements

Outlines wiring needs for ignition systems.

9.3 #SP-028 Optional Fan Kit

10.0 OPERATING INSTRUCTIONS

10.1 Lighting Instructions (#SP-34-LE)

Steps for lighting the SP-34-LE model.

10.2 Lighting Instructions (#SP-34-MV)

Steps for lighting the SP-34-MV model.

10.1.1 Pilot Ignition Selection (IPI;CPI)

10.1.2 Flame Height and Heat Output Adjustment

Adjusting burner flame and heat output for electronic systems.

10.2 Lighting Instructions (#SP-34-MV)

10.2.1 Flame Height and Heat Output Adjustment

Adjusting burner flame and heat output for millivolt systems.

10.2.2 7 Day Time-out Pilot-on-Demand Installations

Details on 7-day timeout for millivolt systems.

11.0 ADJUSTMENT

11.1 Gas Pressure Testing

Instructions for testing gas pressures.

11.1.2 Millivolt Gas Pressure Testing

11.2 Burner Flame Adjustments

11.2.1 Burner Venturi

Instructions for adjusting the burner venturi.

11.2.2 Vent restriction (after installation)

12.0 TROUBLESHOOTING

12.1 Electronic Ignition System

Troubleshooting for electronic ignition systems.

12.2 Continuous Pilot Ignition (Millivolt) System

13.0 MAINTENANCE

13.1 Firebox

Maintenance procedures for the firebox.

13.2 Fan (optional)

Maintenance procedures for the optional fan.

13.3 Vent System

Maintenance procedures for the vent system.

13.4 Glass Assembly

Maintenance procedures for the glass assembly.

13.5 Burner and Pilot System

14.0 REPLACEMENT PARTS LIST

LIMITED LIFETIME WARRANTY

kozy heat SP-34-LE Specifications

General IconGeneral
ModelSP-34-LE
ManufacturerKozy Heat
CategoryIndoor Fireplace
TypeDirect Vent Gas Fireplace
Fuel TypeNatural Gas or Propane
Ignition TypeElectronic Ignition
Log Set MaterialCeramic Fiber
Glass TypeTempered Glass
VentingDirect Vent
Flame ControlVariable
Finish OptionsBlack