EasyManua.ls Logo

kozy heat 932 - User Manual

kozy heat 932
35 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Page 1
INSTALLATION & OPERATING MANUAL
MODELS:
#932 DIRECT VENT WALL-FURNACE
#936 DIRECT VENT WALL- FURNACE
U.S. Patents:
#5.931.154
#6.004.493
IMPORTANT:
READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. FAILURE TO INSTALL
THIS FIREPLACE CORRECTLY CAN CAUSE SERIOUS STRUCTURAL AND FIRE
HAZARDS AND MAY VOID YOUR WARRANTY
.
www.kozyheat.com
July 2006

Other manuals for kozy heat 932

Questions and Answers

  • M
    Miss Abigail WoodAug 8, 2025
    What to do if my Kozy Heat Indoor Fireplace burner won't light?
    • J
      Jonathan AvilaAug 8, 2025
      If the burner on your Kozy Heat Indoor Fireplace won't light, several factors could be the cause. First, ensure the pilot light is lit. Next, check that the regulator valve is turned "on." Also, verify the rocker switch is activated, exposing the "Red" or "on" indicator. If these steps don't work, inspect the rocker switch wire connections and the generator wires at the regulator terminals for looseness. Additionally, check for pinched generator wires. Finally, ensure that any connected wall switch, remote control, or thermostat is properly connected and set.
  • E
    Emily ReynoldsAug 12, 2025
    Why won't my kozy heat 932 pilot stay lit?
    • D
      donnachanAug 12, 2025
      If the pilot light on your Kozy Heat Indoor Fireplace won't stay lit, consider these potential causes: * Ensure you are holding the black control knob in long enough to properly heat the thermocouple. * Check the thermocouple wire connection at the valve to make sure it is secure. * Examine the pilot hood to confirm it's not misdirecting the pilot flame away from the thermocouple; the flame must burn on both the generator and thermocouple.
  • K
    Krista SmithAug 16, 2025
    Why won't my Kozy Heat Indoor Fireplace pilot light?
    • H
      higginsdebraAug 16, 2025
      If the pilot light on your Kozy Heat Indoor Fireplace won't light, check the following: First, ensure the gas supply is turned on. Next, make sure the gas line has been bled out by holding the black control knob in long enough. Finally, verify that you are holding the black control knob in long enough.
  • P
    Patrick MullinsAug 20, 2025
    What to do if my Kozy Heat Indoor Fireplace burner won't stay lit?
    • D
      Dennis WagnerAug 20, 2025
      If the burner on your Kozy Heat Indoor Fireplace won't stay lit, the issue might be related to the wall switch or thermostat wiring. If a wall switch or thermostat is connected with wire that is too thick or runs more than 30 ft, disconnect the wires from the valve. If the burner then stays lit, you should change the location or use the on/off switch only.
  • B
    Beverly PrinceAug 25, 2025
    How to fix no spark when piezo button is depressed on kozy heat 932?
    • C
      Christopher DorseyAug 25, 2025
      If there's no spark when you press the piezo button on your Kozy Heat Indoor Fireplace, try these solutions: First, tighten the nut that holds the piezo in place. Next, ensure the wire on the back of the piezo button is securely connected. Also, check that the wire from the piezo to the electrode is firmly connected at the electrode. Finally, realign the electrode, ensuring there's a 1/8" space between it and the pilot.
  • R
    Robert PerezAug 29, 2025
    Why are the flames lifting on my Kozy Heat Indoor Fireplace?
    • T
      theodorehunterAug 29, 2025
      If the flames on your Kozy Heat Indoor Fireplace are lifting or ghosting, it's likely due to insufficient draft caused by too much restriction. To resolve this, remove the inner ring(s) on the restrictor or remove the restrictor completely.
  • M
    murphyloriSep 2, 2025
    How to fix short, flickering flames on kozy heat 932 Indoor Fireplace?
    • B
      brendawagnerSep 2, 2025
      If your Kozy Heat Indoor Fireplace has short, flickering flames, it's likely due to excessive draft caused by not enough restriction. A simple solution is to add a restrictor.