7-30 BA 35203_04 * 3.0 * 35203_04_07_Wartung.fm
7 Maintenance
Bleeding the fuel system
If the fuel tank has been run empty, or after having performed
maintenance on the fuel system (for example filter replacement, water
separator cleaned, etc.), the fuel system bleeds itself automatically when
starting the engine.
Checking/cleaning the additional fuel filter (water separator, option)
Drain the condensation water in the fuel prefilter at the latest if indicator
light 67
on the instrument panel illuminates.
Drain water more frequently at temperatures around or below 0 °C/32 °F,
otherwise problems can arise even if winter diesel is used.
Injury hazard due to rotating parts!
Rotating parts in the engine compartment can cause serious injury.
► Stop the engine before opening the engine cover.
► Switch off the starter and remove the starting key.
► Switch off the battery master switch (option).
► Apply the parking brake.
1. Lower the loader unit to the ground.
2. Stop the engine and remove the starting key.
3. Apply the parking brake.
4. Open the engine cover.
5. Remove the servicing lid below on the engine vat if necessary
– see “Lower engine vat” on page 7-17.
6. Place a container to collect the fuel.
7. Open drain cock B on the additional fuel filter and drain the
condensation water.
8. Close drain faucet B.
9. Start the engine and check the additional fuel filter for leaks.
Maintenance intervals – see “Maintenance plan” on page 7-3.
Specifications and fill quantities – see “Fluids and lubricants” on
page 7-12.
Have the additional fuel filter A (cartridge) replaced by an authorized
service centre every 500 o/h.
Use a suitable container to collect the fuel as it drains off and dispose of it
in an environmentally friendly manner!