7-52 BA 35203_04 * 3.0 * 35203_04_07_Wartung.fm
7 Maintenance
Inspection and maintenance on the electrical system at regular intervals
CAUTION
Fire hazard! Blown fuses indicate overloading or short circuits of an
electrical component.
Can cause injury.
Have the electrical system checked by an authorised service centre
before inserting new fuses.
In order to avoid damage to the electrical system, use only fuses of the
specified load capacity (amperage).
Information
Observe the maintenance intervals see “Maintenance plan” on page 7-3.
Daily checks before operating the machine
Is the light system OK?
Is the signalling and warning system OK?
Weekly check
Electric fuses: only replace malfunctioning fuses with fuses with the
specified amperage.
Battery charge condition and condition of battery terminals.
Check the electric lines for tightness and chafing and have them
repaired by an authorized service centre if necessary.
Checking the alternator
Only test run the engine with the battery connected.
When connecting the battery, ensure that the poles (+/–) are not
inverted.
Always disconnect the battery before performing welding work or
connecting a quick battery charger.
Have malfunctioning charge indicator lights immediately replaced.