7-72 BA 35203_04 * 3.0 * 35203_04_07_Wartung.fm
7 Maintenance
Setting the lubrication and break times
Break times and lubrication times are set with the notched switches S and P
in the sight window of the controls.
1. Remove the red frame on the protective motor housing of the pump
with a flat screwdriver to set the time.
2. Loosen the four cross-slotted screws and remove the transparent
cover.
3. Set the break time P and the lubrication time S with a flat screwdriver.
4. Install the transparent cover (window) once the settings are performed.
Lubrication times (S)
• 1 to 16 min. (16 notches each up to 1 min.)
• 2 to 32 min. (16 notches each up to 2 min.)
Break time (P)
• 0.5 to 8 h (16 notches, 0.5 h each)
LED (L)
• (B) lubrication system in operation
• (A) lubrication in progress: 0.5 seconds LED ON/0.5 seconds LED OFF
Close the sealing push-in cap of the controls correctly in order to avoid
malfunctions due to the penetration of water in the controls of the
lubrication system!
Filling the central lubrication system
The lubrication system can be filled via the zerk fitting C or a fill coupling
with a manual or pneumatic grease press.
Only fill up to the maximum level in order to ensure the ventilation of the
central lubrication system.
Break time
Fig. 294
Lubrication time
S P L
B
A