BA 35203_04 * 3.0 * 35203_04_07_Wartung.fm 7-83
Maintenance 7
Monitoring the SCR catalytic converter: crystallization
Crystallization occurs when the utilization of the engine is too low or has
too short of operating times.
4
Fig. 306
G
66
Symbol
in field G
Crystallization
message
Result
No symbol appears in the field G of
the digital display.
Warning light 66
does not light up.
No acoustic signal.
Normal operating condi-
tions
The exhaust after-
treatment is in the permis-
sible range.
Symbol G/4 flashes.
Machine operation can be
continued.
Perform manual
regeneration.
Symbol G/4 flashes.
Warning light 66
lights up
continuously.
An acoustic signal
sounds.
Caution! Critical condition
The diesel engine goes
into protective functions
and performance is
reduced by 30%.
Contact an authorized
service centre.
Symbol G/4 flashes
quickly.
Warning light 66
flashes.
An acoustic signal
sounds.
Caution! Critical condition
Diesel engine goes into
protective functions and
performance is reduced
by 30%.
The speed of the diesel
engine is limited.
(1200 rpm).
Contact an authorized
service centre.