VP-439 - The RS-232/Ethernet (UDP) Communication Protocol
Set audio level in specific amplifier stage
Get audio level in specific amplifier stage
P1 (Input/Output)– 0=Input; 1=Output
P2 N/A
P3 – Input=0 to 100, ++/--; Output=0 to 110, ++/--
Set / Get : ~ nn @ MUTE ␠ P1,P2. ␍␊
P1 – 1=Scaler
P2 – 0=Off; 1=On
Response is sent to the com port from which the Set (before execution) / Get command was received
After execution, response is sent to all com ports if CMD-NAME was set any other external control
device (button press, device menu and similar) or genlock status was changed
Mutes the selected audio output