EasyManua.ls Logo

Kramer VP-439 - Page 48

Kramer VP-439
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VP-439 - The RS-232/Ethernet (UDP) Communication Protocol
43
43
Command AUD-LVL
Command Type Audio
Command Name
Permission
Transparency
Set:
AUD-LVL
End User
-
Get:
AUD-LVL?
End User
-
Description
Syntax
Set:
Set audio level in specific amplifier stage
#AUD-LVL P1,P2,P3
Get :
Get audio level in specific amplifier stage
#AUD-LVL? P1,P2
Response
~nn@AUD-LVL P1,P2 ␍␊
Parameters
P1 (Input/Output) 0=Input; 1=Output
P2 N/A
P3 Input=0 to 100, ++/--; Output=0 to 110, ++/--
Command Mute
Command Type [Audio]
Command Name
Permission
Transparency
Set:
MUTE
End User
Public
Get:
MUTE?
End User
Public
Description
Syntax
Set:
Mute the selected output
# MUTE P1,P2
Get :
Mute the selected output
# MUTE? P1
Response
Set / Get : ~ nn @ MUTE P1,P2. ␍␊
Parameters
P1 1=Scaler
P2 0=Off; 1=On
Response triggers
Response is sent to the com port from which the Set (before execution) / Get command was received
After execution, response is sent to all com ports if CMD-NAME was set any other external control
device (button press, device menu and similar) or genlock status was changed
Notes
Mutes the selected audio output

Table of Contents

Related product manuals