EasyManua.ls Logo

Kramer VP-439

Kramer VP-439
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
44
Command Scaler As?
Command Type [Audio]
Command Name
Permission
Transparency
Set:
SCLR-AS
End User
Public
Get:
SCLR-AS?
End User
Public
Description
Syntax
Set:
Set the auto sync off timer
# SCLR-AS P1,P2
Get :
Get the auto sync off timer
definition
# SCLR-AS? P1
Response
Set / Get : ~ nn @ SCLR-AS P1,P2…. ␍␊
Parameters
P1 (Scaler Number) 1=Scaler
P2 (Off/On) 0=Off; 1=Fast; 2=Slow
Response triggers
Response is sent to the com port from which the Set (before execution) / Get command was received
After execution, response is sent to all com ports if CMD-NAME was set any other external control
device (button press, device menu and similar) or genlock status was changed
Notes
Sets the Auto Sync features for the selected Scaler
Command IMAGE PROP
Command Type [Video]
Command Name
Permission
Transparency
Set:
IMAGE-PROP
End User
Public
Get:
IMAGE-PROP?
End User
Public
Description
Syntax
Set:
Set the image size
# IMAGE-PROP P1
Get :
Get the image size
# IMAGE-PROP? P1,…,P6
Response
Set / Get : ~ nn @ IMAGE-PROP P1,P2…. ␍␊
Parameters
P1 (Scaler number) 1=Scaler
P2 (Status) 0=Full; 1=Over Scan; 2=Under Scan; 3=Letter Box; 4=PanScan; 5=Best Fit
Response triggers
Response is sent to the com port from which the Set (before execution) / Get command was received
After execution, response is sent to all com ports if CMD-NAME was set any other external control
device (button press, device menu and similar) or genlock status was changed
Notes
Sets the image properties of the selected scaler

Table of Contents