OPTISONIC 6300 P
Technical Datasheet
Portable ultrasonic clamp-on flowmeter for liquids
User friendly operation using a tablet or smart phone
Quick and easy installation with a wireless web application
Exchangeable transducers mounted in a sensor rails for fast installation and high
performance
© KROHNE 02/2022 - 4000950304 - TD OPTISONIC 6300 P R04 en
Question and Answer IconNeed help?

Do you have a question about the KROHNE UFC 300 P and is the answer not in the manual?

KROHNE UFC 300 P Specifications

General IconGeneral
Housing MaterialAluminum or stainless steel
Measurement PrincipleUltrasonic transit-time
ApplicationLiquid and gas flow measurement
Nominal DiameterDN15...300 (½...12")
Accuracy±1% of reading
Operating Temperature-20°C to +60°C (ambient)
Pressure RatingUp to 40 bar
Output Signals4-20 mA, pulse, frequency
CommunicationHART, Modbus, PROFIBUS DP/PA, Foundation Fieldbus
Power Supply24 V DC
Protection ClassIP67
Temperature Range-40°C to +200°C (medium)

Summary

Product Features

1.1 Portable clamp-on flowmeter

The OPTISONIC 6300 P is a portable ultrasonic clamp-on flowmeter for liquid measurements.

1.2 Variants and options

Details available variants, standard included items, and optional accessories for the flowmeter.

Technical Data

2.1 Technical data

Comprehensive technical specifications for the OPTISONIC 6300 P flowmeter.

Measuring accuracy

Specifies the accuracy and repeatability of the flow measurements.

Electrical connections

Covers power supply, battery, signal cables, USB, and Bluetooth connections.

Installation

3.1 Intended use

Explains the purpose and application scope of the OPTISONIC 6300 P flowmeter.

3.2 Find location and determine data

Guides on selecting the optimal location for transducer mounting on the pipe.

3.2.7 Position of control valve

Recommends positioning relative to control valves for optimal measurement.

3.2.8 Position of pump

Advises on placement relative to pumps for accurate flow readings.

3.3 Start up UFC 300 P signal converter

Guides on charging the converter and installing the mobile application.

3.4 Step 3: Mount the sensor rails

Instructions for mounting sensor rails using metal straps for DN15-250 pipes.

Installation with metal straps (DN15...250)

Step-by-step guide for attaching sensor rails with metal straps.

Installation with nylon straps (> DN250)

Instructions for mounting sensor rails using nylon straps for larger pipe diameters.

3.5 Connect the sensor cable

Guides on connecting the sensor cables to the converter and checking signal strength.

Electrical Connections

4.1 Safety instructions

Outlines crucial safety precautions for electrical connections.

4.2 Power supply

Details the power supply requirements and charging procedures for the converter.

4.3 Connection of the signal cables

Guides on connecting signal cables, ensuring matching calibration numbers.