8 Terminal error messages
8.1 Faults of the electrics/electronics
94
RP701-10 , RP701-11 , RP701-20 , RP701-21 , RP701-30 , RP701-31 , RP701-40 , RP701-41 , RP701-51
Comfort 1.0_en
Possible cause Remedy
The sensor wiring is faulty.
Check sensor and wiring for damage, refer to page73.
522300-
M01
M1
ActuatorM01 “Motor tying 1 (passive)”
Possible cause Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage, refer to page73.
The wiring of the actuator is
faulty.
522301-
K01
ActuatorK01 “Pick-up”
Possible cause Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage, refer to page73.
The wiring of the actuator is
faulty.
522303-
K03
ActuatorK03 “Raising/lowering blade cassette”
Possible cause Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage, refer to page73.
The wiring of the actuator is
faulty.
522320-
K20
B
ActuatorK20 "Blade group B (for the “Hydraulic blade group control system” version)"
Possible cause Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage, refer to page73.
The wiring of the actuator is
faulty.
522321-
K21
A
ActuatorK21 "Blade group A (for the “Hydraulic blade group control system” version)"

Table of Contents