Terminal error messages 8
Faults of the electrics/electronics 8.1
RP701-10 , RP701-11 , RP701-20 , RP701-21 , RP701-30 , RP701-31 , RP701-40 , RP701-41 , RP701-51
Comfort 1.0_en 93
522142-
SensorB42 "Blade group A swivelled out (for the “Hydraulic blade group control
system” version)"
Possible cause Remedy
FMI 4: There is a cable break, cable break/short circuit, general error or undervoltage.
FMI 5: There is a cable break, general error or overload.
The sensor is damaged ex-
ternally.
Check sensor and wiring for damage, refer to page73.
The sensor wiring is faulty.
522143-
SensorB43 "Blade group A swivelled in (for the “Hydraulic blade group control system”
version)"
Possible cause Remedy
FMI 4: There is a cable break, cable break/short circuit, general error or undervoltage.
FMI 5: There is a cable break, general error or overload.
The sensor is damaged ex-
ternally.
Check sensor and wiring for damage, refer to page73.
The sensor wiring is faulty.
522161-
SensorB61 “Tying 1 (passive)”
Possible cause Remedy
FMI 4: There is a cable break, cable break/short circuit, general error or undervoltage.
FMI 5: There is a cable break, general error or overload.
The sensor is damaged ex-
ternally.
Check sensor and wiring for damage, refer to page73.
The sensor wiring is faulty.
522162-
SensorB62 “Tying 2 (active)”
Possible cause Remedy
FMI 4: There is a cable break, cable break/short circuit, general error or undervoltage.
FMI 5: There is a cable break, general error or overload.
The sensor is damaged ex-
ternally.
Check sensor and wiring for damage, refer to page73.
The sensor wiring is faulty.
522163-
SensorB63 "Twine tying mechanism position"
Possible cause Remedy
FMI 4: There is a cable break, cable break/short circuit, general error or undervoltage.
FMI 5: There is a cable break, general error or overload.
The sensor is damaged ex-
ternally.
Check sensor and wiring for damage, refer to page73.