EasyManua.ls Logo

Krone Comprima V 150 - Page 374

Krone Comprima V 150
430 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8 Terminal error messages
8.1 Faults of the electrics/electronics
92
RP701-10 , RP701-11 , RP701-20 , RP701-21 , RP701-30 , RP701-31 , RP701-40 , RP701-41 , RP701-51
Comfort 1.0_en
Possible cause Remedy
FMI 4: There is a cable break, cable break/short circuit, general error or undervoltage.
FMI 5: There is a cable break, general error or overload.
The sensor is damaged ex-
ternally.
Check sensor and wiring for damage, refer to page73.
The sensor wiring is faulty.
522113-
B13
SensorB13 "Twine guide slide position"
Possible cause Remedy
FMI 4: There is a cable break, cable break/short circuit, general error or undervoltage.
FMI 5: There is a cable break, general error or overload.
The sensor is damaged ex-
ternally.
Check sensor and wiring for damage, refer to page73.
The sensor wiring is faulty.
522115-
B15
SensorB15 “Bale ejection”
Possible cause Remedy
FMI 4: There is a cable break, cable break/short circuit, general error or undervoltage.
FMI 5: There is a cable break, general error or overload.
The sensor is damaged ex-
ternally.
Check sensor and wiring for damage, refer to page73.
The sensor wiring is faulty.
522140-
B40
B
OFF
SensorB40 “Blade group B swivelled out (for the “Hydraulic blade group control
system” version)”
Possible cause Remedy
FMI 4: There is a cable break, cable break/short circuit, general error or undervoltage.
FMI 5: There is a cable break, general error or overload.
The sensor is damaged ex-
ternally.
Check sensor and wiring for damage, refer to page73.
The sensor wiring is faulty.
522141-
B41
B
ON
SensorB41 "Blade group B swivelled in (for the “Hydraulic blade group control system”
version)"
Possible cause Remedy
FMI 4: There is a cable break, cable break/short circuit, general error or undervoltage.
FMI 5: There is a cable break, general error or overload.
The sensor is damaged ex-
ternally.
Check sensor and wiring for damage, refer to page73.
The sensor wiring is faulty.

Table of Contents

Other manuals for Krone Comprima V 150

Related product manuals