Terminal error messages 8
Faults of the electrics/electronics 8.1
RP701-10 , RP701-11 , RP701-20 , RP701-21 , RP701-30 , RP701-31 , RP701-40 , RP701-41 , RP701-51
Comfort 1.0_en 91
Possible cause Remedy
FMI 4: There is a cable break, cable break/short circuit, general error or undervoltage.
FMI 5: There is a cable break, general error or overload.
The sensor is damaged ex-
ternally.
Check sensor and wiring for damage, refer to page73.
The sensor wiring is faulty.
522108-
B08
SensorB08 “Blade cassette up”
Possible cause Remedy
FMI 4: There is a cable break, cable break/short circuit, general error or undervoltage.
FMI 5: There is a cable break, general error or overload.
The sensor is damaged ex-
ternally.
Check sensor and wiring for damage, refer to page73.
The sensor wiring is faulty.
522109-
B09
L
SensorB09 “Filling display left”
Possible cause Remedy
FMI 4: There is a cable break, cable break/short circuit, general error or undervoltage.
FMI 5: There is a cable break, general error or overload.
The sensor is damaged ex-
ternally.
Check sensor and wiring for damage, refer to page73.
The sensor wiring is faulty.
522110-
B10
R
SensorB10 “Filling display right”
Possible cause Remedy
FMI 4: There is a cable break, cable break/short circuit, general error or undervoltage.
FMI 5: There is a cable break, general error or overload.
The sensor is damaged ex-
ternally.
Check sensor and wiring for damage, refer to page73.
The sensor wiring is faulty.
522111-
B11
L
SensorB11 “Lock hook bale chamber left”
Possible cause Remedy
FMI 4: There is a cable break, cable break/short circuit, general error or undervoltage.
FMI 5: There is a cable break, general error or overload.
The sensor is damaged ex-
ternally.
Check sensor and wiring for damage, refer to page73.
The sensor wiring is faulty.
522112-
B12
R
SensorB12 “Lock hook bale chamber right”