Terminal error messages 8
Faults of the electrics/electronics 8.1
RP701-10 , RP701-11 , RP701-20 , RP701-21 , RP701-30 , RP701-31 , RP701-40 , RP701-41 , RP701-51
Comfort 1.0_en 95
Possible cause Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage, refer to page73.
The wiring of the actuator is
faulty.
522402-
E02
Actuator E02 “Warning beacon”
Possible cause Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage, refer to page73.
The wiring of the actuator is
faulty.
522420-
E20/E21
ActuatorE20/E21 "Working lights net roll (for the “Net and chamber film wrapping” and
“Working lights” version)"
Possible cause Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage, refer to page73.
The wiring of the actuator is
faulty.
522421-
E21
ActuatorE21 "Working lights chamber film wrapping (for the “Net and chamber film
wrapping” version)"
Possible cause Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage, refer to page73.
The wiring of the actuator is
faulty.
522422-
E22/E23
ActuatorE22/E23 “Maintenance lighting side hood left/right”