EasyManua.ls Logo

Krone Comprima V 150 - Page 378

Krone Comprima V 150
430 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8 Terminal error messages
8.1 Faults of the electrics/electronics
96
RP701-10 , RP701-11 , RP701-20 , RP701-21 , RP701-30 , RP701-31 , RP701-40 , RP701-41 , RP701-51
Comfort 1.0_en
Possible cause Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage, refer to page73.
The wiring of the actuator is
faulty.
522500-
EEPROM
Possible cause Remedy
FMI 13: The wrong configuration values were saved.
An invalid machine type has
been specified.
Adjust the machine type.
Restart the machine.
The configuration parameters
of the machine are invalid.
Configure the machine correctly.
Restart the machine.
522530-
KMB1
Possible cause Remedy
FMI 31: The condition has been fulfilled.
The wiring is faulty.
Check wiring.
The control unit is defective.
Note the error number and the FMI. Then contact the
dealer.
522531-
KMB1
Possible cause Remedy
FMI 19: There is a network/CAN error.
The wiring is faulty.
Check wiring.
The control unit is defective.
Note the error number and the FMI. Then contact the
dealer.
522532-
KMB2
Possible cause Remedy
FMI 31: The condition has been fulfilled.
The wiring is faulty.
Check wiring.
The control unit is defective.
Note the error number and the FMI. Then contact the
dealer.
522533-
KMB2

Table of Contents

Other manuals for Krone Comprima V 150

Related product manuals