-A17-
(2) The strap can not be cut completely
a. The sealing time might be set too short.
b. The strap is not thread correctly so a small part of the strap is not cut completely.
c. The Cutter (H46-40900) is worn.
(3) Error Code
E01:M1 over load.
E02:M2 cannot back to home position.
The SQ1 sensor could be damaged or the connection is loose.
E04:M2 over load.
The strap could be too thick or the H46-40200 Swivel Bracket is not moving smoothly.
E05:PCB overheats.
The tool needs stop working until the PCB cool down to normal temperature.
E07:M1 cannot run.
The wire connection of M1 could be loose or the mechanism is stuck.