R60723.0002–Index6c EN‐page41/62
Continuation„SerialMenu”:
SERIALPROTOCOL
Determinesthesequenceofcharacterssend,whenusingtheserialoutputforcyclicdata
transmissionundertimecontrol(xxxxxxx=valueSERIALVALUE).
Setting„1“removestheunitaddressfromthestringwhichallowsaslightfastertransmission
cycle.
0
Transmissionreport=UnitNr.,+/‐,data,LF,CR
1 1 +/‐ X X X X X X X LF CR
1
Transmissionreport=+/‐,data,LF,CR
+/‐ X X X X X X X LF CR
SERIALTIMER(S)
ThisregisterdeterminesthecycletimeinsecondsforcyclingtransmissionofSERIALVALUEwhen
usingtheserialoutput.(Onaserialrequest,thecyclingtransmissionisstoppedfor20s)
0.000
Allcyclictransmissionisswitchedoff.Theunitwillsenddatauponaserial
requestorwithcommandSERIALPRINT.
…
60.000
Cycletimeinseconds.
SERIALVALUE
Thisparameterdefinesthevaluetobetransmitted.
Setting Code Registercontents
0 :0 Measurement_Result
1 :1 Speed_Value
2 :2 Time_Result
3 :3 Counter
4 :4 Velocity_Speed
5 :5 Batch_Counter
6 :6 Minimal_Value
7 :7 Maximal_Value
8 :8 CounterTotal
9 :9 TimeResultTotal
MODBUS
ThisparameterenablestheModbusprotocolanddeterminestheModbusaddress.
FordetailsoftheModbuscommunicationpleaserefertotheadditionalmanualModbusRTU.
0
Modbusdisabled
SerialinterfaceisusingLecomprotocol(Kueblerdefaultprotocol)
1…247
Modbusenabled:SerialinterfaceisusingModbusRTUprotocol
ThesetvalueistheModbusaddressofthedevice.