R60723.0002–Index6c EN‐page8/62
3 ElectricalConnections
Theterminalscrewsshouldbetightenedwith aslottedscrewdriver(bladewidth2mm).
6.571T.XXX.X0X6.571T.XXX.XAX
3.1 DCPowerSupply
TheunitacceptsDCsupplyfrom18to30Vattheterminals1and2.Thepower
consumptiondependsonthelevelofthesupplyvoltagewithapprox.100mAandthe
additionalcurrentrequiredattheAuxiliaryVoltageOutput.
AllGNDterminalsareinternallyinterconnected.
3.2 AuxiliaryVoltageOutput
Terminal3and4provideanauxiliaryoutputforsupplyofsensorsandencoders.
Theoutputvoltagedependsonthepowersupply.
DCversion ACversion
Theencodervoltageisapprox.1Vlower
thanthepowersupplyvoltageatterminal
1and2andshouldbeloadedwithmax.
250mA.
Theencodervoltageis24VDC(±15%)and
shouldbeloadedwithmax.150mAupto
45degreesCelsius.Athighertemperature
themaximumoutputcurrentisreducedto
80mA.
At6.571T.XXX.XAXdevices,theauxiliaryvoltagesoutputisswitchablefrom24VDCto5
VDC.