EasyManua.ls Logo

Kubler 571T - Command Menu

Kubler 571T
62 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
R60723.0002Index6c EN‐page44/62
5.14 CommandMenu
INPUT1ACTION
Thisparameterdefinesthefunctionoftheinput“Ctrl.In1”.
0 NO Nofunction
1 RESET/SETVALUE
ModeTimer:Resetthevalueto0.
ModeCounter:Reset/setthevaluefromchannelAandBto
„SETVALUE“.
ModeVelocity:Resetthevalueto0.
(d)(s)
2 FREEZE Freezeactualdisplayvalue
(s)
3 KEYLOCK disabletouchscreen
(s)
4 LOCKRELEASE Loosenlockingofalloutputs/relay
(d)
5 RESETMIN/MAX Resetofthemin./max.values
(d)(s)
6 SERIALPRINT Sendingofserialdata,seeparameterSERIALVALUE
(d)
7 TEACHPRESEL.1 CurrentdisplayvalueisstoredasPRESELECTION1
(d)
8 TEACHPRESEL.2 CurrentdisplayvalueisstoredasPRESELECTION2
(d)
9 TEACHPRESEL.3
CurrentdisplayvalueisstoredasPRESELECTION3 (d)
10 TEACHPRESEL.4
CurrentdisplayvalueisstoredasPRESELECTION4 (d)
11 SCROLLDISPLAY Displayswitching(seedisplayinoperationmode)
(d)
12 CLEARLOOPTIME N.A.
13 STARTPRESELECT N.A.
14 ACTIVATE N.A.
15 STOREDATA N.A.
16 TESTPROGRAM N.A.
17 SETREDCOLOR
Thedisplaylightsupred.Thecolorcanbechangedbythe
eventdependentcolorswitchinginthePRESELECTION1...4
(d)
18 SETGREENCOLOR
Thedisplaylightsupgreen.Thecolorcanbechangedbythe
eventdependentcolorswitchinginthePRESELECTION1...4
(d)
19 SETYELLOWCOLOR
ThedisplaylightsupyellowThecolorcanbechangedbythe
eventdependentcolorswitchinginthePRESELECTION1...4
(d)
20 INCREMENTBATCH
Increasethebatchcounter(seemodecounter)
(d)
21 DECREMENTBATCH
Decreaseofthebatchcounter(seemodecounter)
(d)
22 SETBATCH/TOTAL
Reset/setthevalueofthebatchcounter/totalcounter
(seeModeCounter)
(d)(s)
23 INC.BRIGHTNESS Displaybrightnessisincreased
(d)(s)
24 DEC.BRIGHTNESS Displaybrightnessisreduced
(d)(s)
25 SETTOTALTIME Reset/setthetotaltimemeasurement(seeModeTIMER)
(d)(s)
26 SETCounterA
Reset/setthevalueofcounterfromportAtothesetvaluein
SETVALUE‐onlyinMode„COUNTER“possible
(d)(s)
27 SETCounterB
Reset/setthevalueofcounterfromportBtothesetvaluein
SETVALUE‐onlyinMode„COUNTER“possible
(d)(s)
28 LOCKCOUNTERA
Counter(channelA)isdisabledandstopscountingany
furtherpulsesaslongasthiscommandispresent.
(s)
29 LOCKCOUNTERB
Counter(channelB)isdisabledandstopscountinganyfurther
pulsesaslongasthiscommandispresent.
(s)