Mishandling the battery shortens the service life and
adds to maintenance costs.
The
original battery is maintenance-free, but needs
some servicing.
If the battery is weak, the engine will be difficult to start,
and the lights will be dim. It is important to check the
battery periodically.
(1) Battery
(2)
Indicator
1.1 How to read indicator
Check the battery condition by reading the indicator.
Green
Specific gravity of electrolyte and quality of elec-
trolyte are both in good condition.
Black Battery needs charging.
White Battery needs replacing.
1.2 Charging the battery
WARNING
T
o avoid personal injury or death:
• When the battery is being activated, hydrogen
and oxygen gases in the battery are extremely
explosive. Keep open sparks and flames away
from the battery at all times, especially when
charging the battery.
• When charging the battery, ensure the vent
caps are securely in place (if equipped).
• When disconnecting the cable from the battery,
start with the negative terminal first.
When connecting the cable to the battery, start
with the positive terminal first.
• Never check battery charge by placing a metal
object across the posts.
Use a voltmeter or hydrometer.
(1) Battery
1. T
o slow charge the battery, connect the battery
positive terminal to the charger positive terminal
and the negative to the negative, then recharge in
the standard fashion.
2. A boost charge is only for emergencies. It will
partially charge the battery at a high rate and in a
short time. When using a boost-charged battery, it is
necessary to recharge the battery as early as
possible.
Failure to do this will shorten the battery's service
life.
3. The battery is charged when the indicator display
turns from black to green.
4. When exchanging an old battery for a new one, use
a battery of equivalent specification to those shown
in the following table.
[Except LX3310HSDCC]
Battery
type
Volts
(V)
Capaci-
ty at 5
hr (A.H)
Re-
serve
capaci-
ty
(min)
Cold
crank-
ing
amps
(A)
Normal
charg-
ing rate
(A)
55B24L(S)-
MF
12 36 80 430 4.5
[LX3310HSDCC]
Battery
type
Volts
(V)
Capaci-
ty at 5
hr (A.H)
Re-
serve
capaci-
ty
(min)
Cold
crank-
ing
amps
(A)
Normal
charg-
ing rate
(A)
55B24L(S)-
MF
12 46 90 480 4.5
1.3 Directions for battery storage
1. When
storing the tractor for long periods of time,
remove the battery from the tractor, adjust the
electrolyte to the proper level and store in a dry
place out of direct sunlight.
EVERY 100 HOURS  PERIODIC SERVICE