MIDI Mode
The RECEIVE Page
10-11
Using External CCs In Setup Mode, Local Keyboard Channel Off, Input Channel None
TocontrolaprogramparameterviaexternalMIDICCinSetupMode,theparametermustfirst
haveasourceassignedwithintheProgramEditor,asdescribedintheAssigningACCControl
Sourcesectionabove.Tocontrolanassignedparameter,sendthecorrectCCnumbertothe
channelfortheSetup
zonewhichcontainstheprogram.
Using External CCs In Setup Mode, Local Keyboard Channel On, Input Channel None
TocontrolaprogramparameterviaexternalMIDICCinSetupMode,theparametermustfirst
haveasourceassignedwithintheProgramEditor,asdescribedintheAssigningACCControl
Sourcesectionabove.TocontrolanassignedparameterwithaLocalKeyboardChannelset,
sendthecorrectCCnumber
tothechannelsetforLocalKeyboardChannel.(IftheCC#islisted
inthe“ExternalMIDICCRemapping”tablebelow,theCCwillberemappedtothede stination
setforthatphysicalcontrollerintheSetupEditor.Inthiscase,youmustusetheSetupEditorto
assign
thatphysicalcontroller’sdestinationtotheoriginalCCnumberthatyousent.For
destinationsthatshowaname,acorrespondingMIDICCnumbercanbefoundbyfindingthe
nameinTheControllerDestinationList(seepage 7‐22.))
WithintheSetupEditor,youcanalsosetaPC3Kphysicalcontrollerto
sendaCCnumbertoa
programonazone.IfthisisdonewithaLocalKeyboardChannelset,youwillalsobeableto
controlaparameterbysendingthedefaultCCnumberforthatphysicalcontrollertothe
channelsetforLocalKeyboardChannel.Thetablebelow
liststhedefaultCCnumberusedto
controltheassignmentsofPC3KphysicalcontrollerswhileinSetupMode.
Also,foreachphysicalcontroller,ifaCC#islistedinthe“AdditionalMIDICC#WhichAlways
ControlsTheParameterAssignedToEachPC3KPhysicalControllerInSetupMode”column,
thenthatphysical
controller’sassignmentcanalwaysbecontrolledbytheCC#listedinthat
column.Forphysicalcontrollerswherethisisthecase,thephysicalcontroller’sassignmentwill
respondtotheCC#listedinthe“AdditionalMIDICC#WhichAlwaysControlsTheParameter
AssignedToEachPC3KPhysicalControllerInSetupMode”column,
aswellasthephysical
controller’sdefaultCCnumber.
Using External CCs In Setup Mode, Local Keyboard Channel None, Input Channel On
TocontrolaprogramparameterviaexternalMIDICCinSetupMode,theparametermustfirst
haveasourceassignedwithintheProgramEditor,asdescribedintheAssigningACCControl
Sourcesectionabove.TouseanInputChannel(seepage 7‐8,)LocalKeyboardChannelmustbe
settoNone.
Tocontrolanassignedparameterforaprogramonazonethathasan
InputChannelset,sendthecorrectCCnumbertothechannelsetforthatzone’sInputChannel.
(IftheCC#islistedinthe“ExternalMIDICCRemapping”tablebelow,theCCwillbe
remappedtothe
destinationsetforthatphysicalcontrollerintheSetupEditor.Inthiscase,you
mustusetheSetupEditortoassignthatphysicalcontroller’sdestinationtotheoriginalCC
numberthatyousent.Fordestinationsthatshowaname,acorrespondingMIDICCnumber
canbefoundbyfindingthename
inTheControllerDestinationList(seepage 7‐22.))
WithintheSetupEditor,youcanalsosetaPC3KphysicalcontrollertosendaCCnumbertoa
programonazone.IfthisisdonewithaInputChannelset,youwillalsobe abletocontrola
parameterbysendingthe
defaultCCnumberforthatphysicalcontrollertothechannelsetfor
InputChannel.ThetablebelowliststhedefaultCCnumberusedtocontroltheassignmentsof
PC3KphysicalcontrollerswhileinSetupMode.
Also,foreachphysicalcontroller,ifaCC#islistedinthe“AdditionalMIDICC#WhichAlways
ControlsTheParameterAssignedToEachPC3KPhysicalControllerInSetupMode”column,
thenthatphysicalcontroller’sassignmentcanalwaysbecontrolledbytheCC#listedinthat
column.Forphysicalcontrollerswherethisisthecase,thephysicalcontroller’sassignmentwill
respondtotheCC#listedinthe“Additional
MIDICC#WhichAlwaysControlsTheParameter
AssignedToEachPC3KPhysicalControllerInSetupMode”column,aswellasthephysical
controller’sdefaultCCnumber.