THERMOSTAT INSPECTION
Suspend the thermostat in a pan of water
over a burner and gradually raise the water
temperature to check its operation.
Technical Data
THERMOSTAT INSTALLATION
The installation sequence is the reverse of
removal.
Fill the cooling system with the specified
coolant. (
!
3-9)
• Do not let the thermostat touch the pan
as it will give a false reading.
• Replace the thermostat if the valve
stays open at room temperature.
•Test the thermostat after it is opened
for about 5 minutes and holds the
temperature at 70℃ .
Replace the O-ring with a new one and
apply grease to it.