14. BATTERY/CHARGING SYSTEM/
A.C. GENERATOR
14-5
CHARGING
Connect the charger positive (+) cable to the
battery positive (+) terminal.
Connect the charger negative (-) cable to the
battery negative (-) terminal.
Charging current: Standard : 0.4 A
Quick : 4 A
Charging time : Standard : 510 hours
Quick : 30 minutes
After charging: Open circuit voltage: 12.8 V
min.
Keep flames and sparks away from a
charging battery.
Turn power ON/OFF at the charger, not
at the battery terminals to prevent
sparks near the battery to avoid
explosion.
Charge the battery according to the
ifi d h b
Quick charging should only be done in
an emergency.
Measure the voltage 30 minutes after
the battery is charged.
Power Lam
p
(
Red
)
Charging Lamp
(Green)
Red
Blac
k

Table of Contents

Questions and Answers: