2T6/2T7/2T8/2T9
1-5-29
1-5-11 Others
(1) Detaching and refitting the main driving motor unit
Procedure
1. Remove the right upper cover.
(See page 1-5-4)
2. Remove the right lower cover.
(See page 1-5-4)
3. Pull the connector out from the motor 
and then release the wires from wire 
holder.
4. Remove three screws and then remove 
the main driving motor unit.
5. Check or replace the main driving motor 
unit and refit all the removed parts.
Figure 1-5-47
Figure 1-5-48
Connector
Wires
Wire
holder
Main driving 
motor unit
Screw
Screw
Screw
Connector
(60/55/50 ppm)
Wires
Wire
holder
Main driving 
motor unit
Screw
Screw
Screw
Connector
(45 ppm)