2P7/2R0/3PN
1-5-53
20. Remove three screws and then remove
the controller box cover.
Figure 1-5-97
21. Remove the grounding wire by remov-
ing the screw.
22. Remove three screws and then remove
the eject unit.
23. Check or replace the power source
PWB assembly and refit all the
removed parts.
Figure 1-5-98
Controller box cover
Screw
Screw
Screw
Power source
PWB assembly
Screw
Screw
Screw
Screw
Grounding wire