2F8/2F9/2GA-1
1-5-32
(3) Detaching and refitting the laser scanner unit
Procedure
1. Remove the top cover (See page P.1-5-2).
2. Remove the right cover (See page P.1-5-3).
3. Remove the three/four connectors from the
main PWB.
4. Remove the four screws and then remove
the laser scanner unit.
5. Check or replace the laser scanner unit and
refit all the removed parts.
Figure 1-5-44
Screw
Screw
Laser scanner unit
Connectors (three/four)
45/47 ppm printer
(EUR/USA model)
only
Screw
Screw
45/47 ppm printer
(EUR/USA model)
only