2F8/2F9/2GA-5
1-4-5
6000 Broken fuser heater lamp wire
The temperature does not reach 100
°C/
212
°F after the fuser heater lamp has
been turned on continuously for 30 s.
30/31 ppm printer (EUR/USA model):
The temperature does not rise by 1°C/
1.8
°F after the fuser heater lamp has
been turned on continuously for 5 s dur-
ing printing.
35/37 and 45/47 ppm printers (EUR/USA
model):
Fuser thermistor M detection
temperature does not rise by 1
°C/1.8°F
after the fuser heater lamp has been
turned on continuously for 10 s during
warm-up or at standby.
Fuser thermistor S detection
temperature does not rise by 1°C/1.8°F
after the fuser heater lamp has been
turned on continuously for 5 s during
warm-up or at standby.
The temperature does not rise by 1°C/
1.8
°F after the fuser heater lamp has
been turned on continuously for 5 s dur-
ing printing.
Poor contact in the
fuser thermistor M
connector termi-
nals.
Reinsert the connector (See page P.1-5-19).
Fuser thermistor M
installed incor-
rectly.
Check and reinstall if necessary (See page
P.1-5-19).
Thermal cutout
triggered.
Check for continuity. If none, replace the
thermal cutout (See page P.1-5-19).
Fuser heater lamp
installed incor-
rectly.
Check and reinstall if necessary (See page
P.1-5-19).
Broken fuser
heater lamp wire.
Check for continuity. If none, replace the
fuser heater lamp (See page P.1-5-15).
6020 Abnormally high fuser thermistor M
temperature
30/31 ppm printer (EUR/USA model):
The temperature of the fuser thermistor
M detects 250
°C/482°F or more continu-
ously for 3 s.
35/37 and 45/47 ppm printers (EUR/USA
model):
The temperature of the fuser thermistor
M detects 240
°C/464°F or more continu-
ously for 3 s.
Shorted fuser ther-
mistor M.
Measure the resistance. If it is 0 W, replace
the fuser thermistor M (See page P.1-5-19).
Defective engine
PWB.
Replace the engine PWB (See page P.1-5-
22).
6030 Broken fuser thermistor M wire
30/31 ppm printer (EUR/USA model):
Input from fuser thermistor M is less than
1 (A/D value) for more than 1 s.
35/37 and 45/47 ppm printers (EUR/USA
model):
Input from fuser thermistor M is less than
1 (A/D value) for more than 3 s.
Poor contact in the
fuser thermistor M
connector termi-
nals.
Reinsert the connector (See page P.1-5-19).
Broken fuser ther-
mistor M wire.
Measure the resistance. If it is ∞ Ω, replace
the fuser thermistor M (See page P.1-5-19).
Fuser thermistor M
installed incor-
rectly.
Check and reinstall if necessary (See page
P.1-5-19).
Thermal cutout
triggered.
Check for continuity. If none, replace the
thermal cutout (See page P.1-5-19).
Fuser heater lamp
installed incor-
rectly.
Check and reinstall if necessary (See page
P.1-5-15).
Broken fuser
heater lamp wire.
Check for continuity. If none, replace the
fuser heater lamp (See page P.1-5-15).