EasyManua.ls Logo

Kyocera FS-600 - Environmental and Installation Requirements

Kyocera FS-600
83 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Environmental Requirements of the Page Printer
4
Grounding
Be sure to connect the ground wire for the printer's power supply to the ground terminal of the power
outlet, to a copper pole buried at least 65 cm (25 inches) in the ground, or to a water pipe approved by
the water department for use as a ground.
WARNING
Never use a gas pipe as a ground, as this may result in fire.
Surrounding space
Space surrounding the location where the printer is installed is required as shown below for purposes of
ventilation and maintenance.
WARNING
Be sure to secure enough space surrounding the printer. Continued use without enough space
may cause heat to build up within the printer, resulting in fire.
30 cm (11.8 inches)
50 cm (19.6 inches)
40 cm (15.7 inches)
25 cm (9.8 inches)
5 cm (2 inches)