2LK/2LN/2LM/2LC
2-3-70
YC3
1 +24V1 O 24 V DC 24 V DC power to EPWB
Connected to
engine PWB
2 +24V1 O 24 V DC 24 V DC power to EPWB
3 GND - - Ground
4 GND - - Ground
5 +12V O 12 V DC 12 V DC power to EPWB
6 GND - - Ground
7 +5V O 5 V DC 5 V DC power to EPWB
8 GND - - Ground
YC4
1 +24V1 I 24 V DC 24 V DC power from PSPWB
Connected to
power source
PWB
2 +24V1 I 24 V DC 24 V DC power from PSPWB
3 +24V1 I 24 V DC 24 V DC power from PSPWB
4 +12V I 12 V DC 12 V DC power from PSPWB
5 GND - - Ground
6 GND - - Ground
7 GND - - Ground
8 GND - - Ground
YC5
1 GND - - Ground
Connected to
power source
PWB
2 DRM_HEAT_REM O 0/3.3 V DC FH: On/Off
3 POWER_OFF O 0/3.3 V DC Sleep mode signal: On/Off
YC10
1 GND - - Ground
Connected to
ID sensor1/2
and cleaning
solenoid
2 M_TEMP - - Not used
3 3.3V O 3.3 V DC 3.3 V DC power to IDS1
4 REG_F_LED O Analog IDS1 control signal
5 GND - - Ground
6 REG_SENS_F_P I Analog IDS1 detection signal
7 REG_SENS_F_S I Analog IDS1 detection signal
8 3.3V O 3.3 V DC 3.3 V DC power to IDS2
9 REG_R_LED O Analog IDS2 control signal
10 GND - - Ground
11 REG_SENS_R_P I Analog IDS2 detection signal
12 REG_SENS_R_S I Analog IDS2 detection signal
13 24V O 24 V DC 24 V DC power to CLSOL
14 CLN_SOL_REM O 0/24 V DC CLSOL: On/Off (ACT)
15 CLN_SOL_RET O 0/24 V DC CLSOL: On/Off (RET)
Connector Pin Signal I/O Voltage Description