2LK/2LN/2LM/2LC-2
2-3-73
YC17
15 MPF_WID3 I 0/3.3 V DC MPPWSW: On/Off
Connected to
relay PWB
16 MPF_WID2 I 0/3.3 V DC MPPWSW: On/Off
17 MPF_WID1 I 0/3.3 V DC MPPWSW: On/Off
18 MPF_TABLE I 0/3.3 V DC MPTSW: On/Off
19 GND - - Ground
20 GND - - Ground
YC18
1 FSR_MOT_BRK O 0/3.3 V DC FUM break signal
Connected to
fuser motor
2 FSR_MOT_DIR O 0/3.3 V DC FUM drive switch signal
3 FSR_MOT_RDY I 0/3.3 V DC FUM ready signal
4 FSR_MOT_CLK O 0/3.3 V DC (pulse) FUM clock signal
5 FSR_MOT_REM O 0/24 V DC FUM: On/Off
6 GND - - Ground
7 24V2 O 24 V DC 24 V DC power to FUM
YC19
1 EXIT_REAR_FAN O 0/24 V DC ERFM: On/Off
Connected to
eject rear fan
motor
2 +24V1 O 24 V DC 24 V DC power to ERFM
YC20
1 JOB_SET I 0/3.3 V DC Job separator set signal
Connected to
job separator
2 GND - - Ground
3 GND - - Ground
4 JOB_MOT_REM O 0/24 V DC JSEM: On/Off
5 24V1 O 24 V DC 24 V DC power to JSMPWB
6 JOB_MOT_CLK O 0/3.3 V DC (pulse) JSEM clock signal
7 5V O 5 V DC 5 V DC power to JSMPWB
8 JOB_MOT_DIR O 0/3.3 V DC JSEM drive switch signal
9 JOB_OPEN_SEN
S
I 0/3.3 V DC JSOCS: On/Off
10 JOB_SOL_REM O 0/24 V DC JSFSSOL: On/Off
11 NC - - Not used
YC22
1 24V2 O 24 V DC 24 V DC power to RCL
Connected to
registration
clutch
2 REG_CL_REM O 0/24 V DC RCL: On/Off
Connector Pin Signal I/O Voltage Description