General safety guidelines and explanations of hazard symbols like Danger, Warning, and Caution.
Specific precautions for handling electrical shock, scalding, equipment damage, static electricity, and wet hands.
Defines the manual's purpose, scope, abbreviations, and key terminology.
Describes the system components and provides sample configurations for different rooms.
Details specifications for Operator Console components like monitors, PCs, and control panels.
Details specifications for the Logic Module, including its type, operating frequency, and memory capacity.
Details specifications for Electronic Terminal modules like ET-PIO2 and MMIF2.
Details specifications for Journal Module components like ZPEN3, ZNIO2, ZSIO2, and KDD172-KY48-2.
Precautions for operator console usage, including posture, display adjustment, and mouse cleaning.
Step-by-step guide for removing and inserting cards and IC cards safely.
Precautions for handling Logic, Electronic Terminal, Relay, Connector, and Optical Fiber modules.
Precautions for Power Supply Units inside the control rack, including voltage checks and main power switch locations.
Describes the Logic Module, including card mounting views, configurations, and power supply.
Describes the Electronic Terminal Module, including sub-rack views, card functions, and configurations.
Describes Operator Console and Maintenance Console mounting views and MMIF2 Terminal cards.
Describes the Journal Module, including its components, system configuration, and failure messages.
Describes the start-up procedures for the EI System, Operator Console, Logic Rack, and Terminal Rack.
Explains LED indications, switches, and setup for Logic Module cards like IPU6C and F486-4I.
Explains LED indications and switch functions for Electronic Terminal Module cards (LINE2B, ET-PIO2, LINEM2, MMIF2, SPHC-TT).
Details LED indications, switches, ports, and terminals for Journal Module cards like ZPEN3, ZNIO2, ZSIO2, and KDD172-KY48-2.
Details unit setup procedures, including polarity keys, board settings, and connector configurations.
Describes wiring practices, colour coding for wires/cables, and labeling for identification.
Details surge protection practices, power protection strategies, and interface protection for the EI system.
Provides a diagram illustrating the typical system configuration of the K5BMC EI System.
Illustrates typical vital input/output and non-vital input/output circuits using ET-PIO2 and MMIF2 modules.
Shows typical inter-rack optical fiber cable connections between different system components.
Explains the rationale behind not earthing the K5BMC EI system and related countermeasures.
Details provisions and measures for preventing lightning damages and surge influx to the EI system.
Checklist items for inspecting installation status regarding grounding and lightning protection in the equipment room.
Checklist items for visual inspection of power devices, ladders, cable paths, and logic/relay racks.
Checklist items for verifying wiring and routing of K5BMC EI logic rack, relay rack, and CCIP components.
Checklist items to verify system status after turning on K5BMC EI, including power supplies and indicators.
Describes functional tests for system changeover, route setting, point control, and interlocking logic.
Procedures for fault information inspection of logic and electronic terminal cards, covering failure scenarios.
Procedures for inspecting signal sequence and fail-safe related functions like HBP and PORBP.
Tests for Data Logger connection and real-time synchronous data transmission checks.
| Category | Controller |
|---|---|
| Manufacturer | Kyosan |
| Safety Integrity Level | SIL4 |
| Redundancy | Dual Redundant |
| Communication Interface | Ethernet, Serial |
| Operating Temperature | -40°C to +70°C |
| Humidity Range | 5% to 95% non-condensing |
| Application | Railway signalling |