Document No. Z914 – C36000245 Ver. 1
Hand Book for Electronic Interlocking model K5BMC - Installation, Maintenance & Trouble Shooting -
25. Apr. 2014 P- 62/123
3
2
1
D7 D3
D4 D0
D6 D2
D5 D1
T
R
T
R
R
T
FSIO-EX
WT
KYOSAN
7.2.4 FSIO-EX Card
1) LED-Indications
D0 to D7
Status of software (Refer to Table 1.3.1)
WT:
NOT USED.
Show status of ET SIO lines.
Blink = Have transfer data, OFF= No transfer data
1 T: Line 4 Self SYS Sending
1 R(left): Line 4 Self SYS Receiving
1 R(right): Line 4 Other SYS Receiving
2 T: Line 5 Self SYS Sending
2 R(left): Line 5 Self SYS Receiving
2 R(right): Line 5 Other SYS Receiving
3 T: Reserved
3 R(left): Reserved
3 R(right): Reserved
Table 1.3.1
LED Information Normal Failure
D0 LED output (50ms) Blink ON or OFF
D1 Initialize processing Blink ON (Initial processing start)
OFF (Initial processing finish)
D2 DPRAM read processing Blink ON (DPRAM read processing start)
OFF (DPRAM read processing finish)
D3 DPRAM write processing Blink ON (DPRAM write processing start)
OFF (DPRAM write processing finish)
D4 MTC Tx/Rx processing OFF ON (DPRAM initialization is not finished)
D5 Transmission speed ON or
OFF
ON (1.2Mbps)
OFF (307.2Kbps)
D6 Interrupt MTC Tx/Rx Blink ON (Interrupt processing start)
OFF (Interrupt processing finish)
Initial RAM check error (When D0 is OFF) D7 System Error OFF ON
Idle time RAM check error (When D0 is
ON)