MTC Failure Display Specification for K5BMC EI
Document No. Z914-C73000030E Ver. 5
12. Feb. 2011 P 16 / 25
4.3 The List of Status Level of Other Block
4.3.1 MMIF for Control Panel
1) MMIF Sub-Rack for Control Panel
2) Card for
LINEM2
3)
Card for MMIF2
*The corresponding yellow message pop-up screen will appear on MTC for the ease of maintenance.
Tes t
No.
Check Item Relay Name
Nomal
bit status
Note
1
S1 LINEM2
CP-S1-LINEM2-FL
1
*
2
S2 LINEM2
CP-S2-LINEM2-FL
1
*
3
S1 MMIF2 -1
CP-S1-MM-1-FL
1
*
4
S1 MMIF2 -2 CP-S1-MM-2-FL 1
*
5
S1 MMIF2 -3 CP-S1-MM-3-FL 1
*
6
S1 MMIF2 -4 CP-S1-MM-4-FL 1
*
7
S1 MMIF2 -5 CP-S1-MM-5-FL 1
*
8
Logic Rack
Push Button
9
CONTROL PANEL
Push Button
10
OPC
Push Button
11
MTC
Push Button
12
OUT FIELD
EQUIPMENT
Push Button
Tes t
No.
Check Item Message in case of failure occurs/recovers Relay Name
Nomal
bit status
Note
1 ETCtrl Data OE Transform CCIP_S1_LINEM2 ET-Ctrl-Data-OE_fail S1-LINEM-OE-FL
1
*
2 ET Indic. Data EO Transform CCIP_S1_LINEM2 ET-Indic.-Data-EO_fail S1-LINEM-EO-FL
1
*
3 DC24/DC5 CCIP_S1_LINEM2 DC24/DC5_fail S1-LINEM-D24-5-FL
1
*
4 ETCtrl Data OE Transform CCIP_S2_LINEM2 ET-Ctrl-Data-OE_fail S2-LINEM-OE-FL
1
*
5 ET Indic. Data EO Transform CCIP_S2_LINEM2 ET-Indic.-Data-EO_fail S2-LINEM-EO-FL
1
*
6 DC24/DC5 CCIP_S2_LINEM2 DC24/DC5_fail S2-LINEM-D24-5-FL
1
*
Tes t
No.
Check Item Message in case of failure occurs/recovers Relay Name
Nomal
bit status
Note
1 ETCtrl Data Rx CCIP_S1_MMIF2-n ET-Ctrl-Data-Rx_fail S1-MM-n-Rx-FL
1
n=1 to 5 *
2 ET Indic. Data Tx CCIP_S1_MMIF2-n ET-Indic.-Data-Tx_fail S1-MM-n-Tx-FL
1
n=1 to 5 *
3 MMIF2 ID CHECK CCIP_S1_MMIF2-n MMIF2-ID-CHECK_fail S1-MM-n-IDCHECK-FL
1
n=1 to 5 *
4 I/O-1 CCIP_S1_MMIF2-n I/O_fail S1-MM-n-IO-FL
1
n=1 to 5 *