Rigging procedures
Stacking Syva on Syva Low
type of deployment stacked
rigging accessories Syva Base
tools torque screwdriver
T25 Torx bit
T30 Torx bit
additional material 4 x 6 mm (0.2 in) screws depending on oor material (optional)
min number of operators 1
Procedure
Risk of crushing injury
Always hold Syva Base by the handle.
Secure Syva Base on the bottom of Syva Low and stack Syva on top.
Store plates and unused screws in Syva Cov.
T25
3 N.m
T30
x4
Ø
6 mm /
0.2 in
Syva rigging manual (EN) version 1.1 24