MALFUN.
CODE
051
052
053
054
055
066
067
091
092
SOLUTIONS
15. Defects - Malfunctions
POSSIBLE CAUSESDESCRIPTION
Boiler temperature
malfunctioning
Boiler heating timeout
Steam thermocouple
Value is outside of acceptable
range
Disconnected
thermocouple
Malfunctioning card
Open the machine
- Check cabling
- Replace the thermocouple
- Replace the card
The safety thermocouple
has been triggered
The resistance is
interrupted (cabling
defect)
The Triac card is
malfunctioning
Open the machine
- Check if the safety thermostat has been triggered, and
reset it if necessary
- Check if there are interruptions or detached fastons on the
cabling
- Check that the boiler resistance is not interrupted and
replace it if necessary
- Replace the Triac card
KTY plugs
Value is outside of acceptable
range
KTY plugs
Timeout plug resistance activation
1 Open the machine
2 Activate the test panel
3 Use test panel to check if the counter function works
during coffee dispensing
- If the counter works only with a few impulses:
- Check the granulometry and quality of the ground coffee
- Clean the filters
- Check if the coffee solenoid valve and coffee hydraulic
circuit are clogged
- If the counter does NOT function:
- Check if there is water and if the pump works
- Replace the turbine
- Check the cabling
Failure to read impulses by
volumetric meter of turbine
during coffee dispensing
No water
Broken pump
Too much coffee
Coffee ground too fine
Clogged filters
Coffee solenoid valve
clogged or defective
Broken turbine
Failure to read impulses by
volumetric meter of turbine
during circuit wash cycle
No water
Broken pump
Clogged filters
Coffee solenoid valve
clogged or defective
Broken turbine
1 Open the machine
2 Activate the test panel
3 Use test panel to check if the counter function works
during the wash cycle
- If the counter works only with a few impulses
- Clean the filters
- Check if the coffee solenoid valve and coffee hydraulic
circuit are clogged
- If the counter does NOT function:
- Check if there is water and if the pump works
- Replace the turbine
- Check the cabling
Timeout scheduled daily unit
wash cycle
A unit wash cycle was not
performed within 60 minutes
of the message.
Timeout scheduled daily milk
circuit wash cycle
A milk circuit wash cycle was
not performed within 60
minutes of the message.