4. Programming
How to enter Programming menu: Insert the smart card.
Besides the date and hour, the word TECHNICIAN will appear.
Access to menus: Use the + (30) and - (31) keys to position
the cursor on the desired line, then press the PRG (29) key.
Access and modification of sub-menus: Use the + (30) and -
(31) keys to position the cursor on the desired line, then press the
PRG (29) key.
Use the + (30) and - (31) keys also to modify the message or
number, then press the RES (24) key to confirm the data.
Note: When modifying data, the cursor changes from nto "à".
Exiting the programming menu: Always press the RES (24)
key to confirm/exit the menu.
14 January 2004
wednesday 15:15:04
Technician
Display of available menus: Press the PRG (29) key.
à
u
u
+
-
+
u
Press one of the coffee dispensing keys (32) (the relative led will
remain on, not flashing). The following message will appear on the
display:
5. Key menu - Coffee selection
The following coffee selection parameters can be modified:
- type (key personalizing, e.g.: 1 coffee, 1 cappuccino, 2 coffee,
2 cappuccini, fast washing, stop, null);
- water dose (volumetric dosage pulses, from 0 to 999, with
increments of 1);
- MSx dose coffee (left grinde encoder pulses, 0 ÷ 200 with
increments of 1);
- MDx dose coffee (right grinde encoder pulses, 0 ÷ 200 with
increments of 1);
- backing (the return time for the chamber, which can be adjusted
for each key: from 0 to 6 with increments of 0.1 seconds);
- infusion (infusion time: 0 ÷ 6 seconds, with increments of 0.1);
- pressure release (pressure release time: 0 ÷ 5 seconds, with
increments of 0.1)
- drying (pod drying time; 0 ÷ 5 seconds, with increments of 0.1).
Note: the coffee doses for both grinders set in the technical
programming menu, are subject to change in the customer
programming menu within a range of + 10 of the set value.
+
u
+
u
Þ TECHNICAL PROG.
KEY MENU
CONFIGURATION
TESTING
WEIGHTING
Þ KEY MENU
Type 1 coffee
Water dose 090
MSX cof, dose 043
MDX cof, dose 000
Backing 00.2
Infusion 00.3
Prs. discharged 00.5
Þ KEY MENU
Type 1 coffee
Water dose 090
MSX cof, dose 043
MDX cof, dose 000
Backing 00.2
Infusion 00.3
Prs. discharged 00.5
Þ KEY MENU
Type 1 coffee
Water dose 090
MSX cof, dose 043
MDX cof, dose 000
Backing 00.2
Infusion 00.3
Prs. discharged 00.5