39E Operating instructions
Page
7 / 8
───────────────────────────────────────────────────────────
──
SW V1.01 11.09.2005
La Gard Latin America - 741 Shotgun Rd. – Sunrise Florida – 33351 – USA
Tel. +1 954 476 5574 – Fax. + 7 954 476 5576 – Email: info@lagardlat.com
To get audit file (special function #7)
Enter special function #7, but before pressing on ‘7’, connect serial adapter to TAG reader, and start acquisitionon
connected device.
Audit file is transmitted to serial interface.
After transmission, LED is still on a during search of audit beginning into memory.
Notes:
Manager only.
Audit file is automatically printed at each power-up (except in pre-setup mode).
Audit printing may be stopped by sending a break signal to lock (or keeping down ‘0’ key).
Audit file can not be cleared. When memory is full, older events are replaced by newer.
To check user status (special function #7b)
Enter special function #7, holding down function number until double beep.
By pressing user ID, you get his status: 1 beep = active, 2 = disabled, 3 = does not exist, long = blocked, not
available.
Enter ‘0’ to exit function.