Voltage Peak Limiter Load vs Power Tables
FP+ Series: Dedicated Touring Amplifiers
FP+ Series amplifiers include the user-definable Voltage Peak Limiter (VPL) function. Rear-panel DIP-switch settings allow the output voltage
to be adjusted and consequently the output power available. The following tables provide information, for the four FP+ Series models, about
resultant output power at typical loads (single channel and bridged operation) with the available VPL settings.
V peak Vrms
16 ! 8 ! 4 ! 2 !
195 V 195 138 1200 2400 4800 6500
170 V 170 120 860 1720 3445 6500
140 V 140 99 620 1245 2485 4970
116 V 116 82 445 885 1770 3540
100 V 100 70 320 640 1275 2550
80 V 80 57 230 460 925 1850
66 V 66 47 170 340 665 1330
54 V 54 38 120 240 480 960
VPL Setting
V peak Vrms
16 ! 8 ! 4 ! 2 !
195 V 390 276 4800 9600 13000 n.r.
170 V 340 240 3445 6890 13000 n.r.
140 V 280 198 2485 4970 9940 n.r.
116 V 232 164 1770 3540 7080 n.r.
100 V 200 142 1275 2550 5100 n.r.
80 V 160 114 925 1850 3700 n.r.
66 V 132 94 665 1330 2665 n.r.
54 V 108 76 480 960 1920 n.r.
Output power bridged per two channels
Output power per channel (W)
V peak Vrms
16 ! 8 ! 4 ! 2 !
155 V 155 110 750 1500 3000 3500
121 V 121 86 460 915 1830 3500
101 V 101 70 320 640 1275 2550
83 V 83 59 215 430 860 1720
70 V 70 49 155 305 615 1225
56 V 56 40 100 195 390 785
47 V 47 33 70 140 275 550
38 V 38 27 45 90 180 360
VPL Setting
V peak Vrms
16 ! 8 ! 4 ! 2 !
155 V 310 220 3000 6000 7000 n.r.
121 V 242 172 1830 3660 7000 n.r.
101 V 202 140 1275 2550 5100 n.r.
83 V 166 118 860 1720 3445 n.r.
70 V 140 98 615 1225 2450 n.r.
56 V 112 80 390 785 1570 n.r.
47 V 94 66 275 550 1105 n.r.
38 V 76 54 180 360 720 n.r.
Output power per channel (W)
Output power bridged per two channels