USER MANUAL HEADLINES
Unpacking 2
Warnings 2
User responsibility 2
1. Speaker damage
2. Speaker output hazard.
3. Radio interference.
Introduction 3
1. Front panel
2. Rear panel
Installation 4
1. Mounting
2. Cooling
3. Operating voltage
4. Grounding
5. Power consumption
6. Input connections
7. Connecting speakers
8. Impedance matching (MLS-switches)
Operation modes 7
1. Stereo
2. Tandem mono
3. Bridged mono
4. Stereo reverse
Operation 8
1. Operation precautions
2. Powering up -Soft start
3. Input attenuators
4. Gain switch
5. Indicators
Protections 9
1. Clip-limiter
2. Thermal protection
3. VHF protection
4. Short circuit protection
5. AC mains voltage protection
6. D.C. protection
LAB 2002
USER MANUAL
Design features 10
Cooling
Light weight
Regulated power supply
Safety approvals
EMC approvals
Specifications 11
EMC-declaration
Appendix A 12
Mains voltage selection
Maintenance 12
Troubleshooting 12
Warranty and disclaimers 13
General
International
Technical assistance and services 13
International
Factory services
1

Other manuals for Lab.gruppen LAB 2002

Question and Answer IconNeed help?

Do you have a question about the Lab.gruppen LAB 2002 and is the answer not in the manual?

Lab.gruppen LAB 2002 Specifications

General IconGeneral
BrandLab.gruppen
ModelLAB 2002
CategoryAmplifier
LanguageEnglish

Summary

Unpacking

Warnings

User Responsibility

Speaker Damage

Potential danger to loudspeakers and humans from overpowering or high signal levels.

Speaker Output Hazard

Hazardous output voltages exist. Avoid touching exposed speaker wiring while operating.

Radio Interference

Product compliance with EMC directive; potential interference issues and mitigation.

Introduction

Front Panel Overview

Description and function of all front panel controls and indicators.

Rear Panel Overview

Description of rear panel connectors, switches, and indicators.

Installation

Mounting, Cooling, and Operating Voltage

Details on rack mounting, cooling system, and operating voltage selection.

Grounding, Power Consumption, and Input Connections

Information on grounding, power draw, and connecting audio inputs.

Operation Modes

Stereo Operation

Dual channel operation with independent level control per channel.

Tandem Mono

Single input drives both channels independently for mono output.

Bridged Mono

Combines both channels for higher mono output power.

Stereo Reverse

Channel B phase reversed for improved power supply efficiency.

Operation

Operation Precautions

Key safety checks and best practices before and during operation.

Powering Up - Soft Start

Describes the amplifier's internal circuit check and fan sequence on power-up.

Input Attenuators

Details on using front panel controls to adjust input signal level.

Gain Switch

Explanation of how to adjust input sensitivity for different signal levels.

Protections

Clip Limiter

Prevents speaker damage by limiting output signal distortion.

Thermal Protection

Mutes input signal if amplifier overheats to prevent damage.

VHF Protection

Mutes input signal if high frequency signals exceed limits for extended periods.

Short Circuit Protection

Protects output devices from damage due to short circuits.

AC Mains Voltage Protection

Shuts down the amplifier if AC mains voltage is outside operating range.

D.C. Protection

Detects and protects against DC voltage on output channels.

Design Features

Cooling System

Details the patented Intercooler system for efficient heat dissipation.

Light Weight Construction

Highlights the amplifier's low weight due to SMPS and alloy chassis.

Switch Mode Power Supply (SMPS)

Explains the regulated SMPS technology and its benefits.

Minimum Load Switches (MLS)

Describes MLS switches for impedance matching and power allocation.

Specifications

Safety Approvals

Lists safety certifications like IEC65 and EN 60065.

EMC Approvals

Details compliance with Electro Magnetic Compatibility standards.

Appendix A

Mains Voltage Selection

Procedure for selecting between 115V and 230V AC operation.

Maintenance

Troubleshooting

No Output Fault

Troubleshooting steps for when the amplifier produces no sound.

Thermal Protection Fault

Diagnosing thermal protection activation at low levels.

Protect Mode Fault

Checking AC line voltage and potential internal fuse issues.

Warranty and Disclaimers

General Warranty Terms

Details the one-year warranty, repair/replacement policy, and exclusions.

International Warranty

Guidance to contact local suppliers for country-specific warranty information.

Technical Assistance and Services

International Service Contact

How to find authorized service centers or contact LAB.GRUPPEN for repair.

Factory Service Procedures

Instructions for returning products for factory service, including required documentation.