Do you have a question about the Lab.gruppen SS 1300 and is the answer not in the manual?

Lab.gruppen SS 1300 Specifications

General IconGeneral
Power Output1300 W
Channels2
THD<0.1%
Damping Factor> 200
Output Power per channel 2 ohms1300 W
Output Power per channel 8 ohms500 W
2 ohms bridged2600 W
8 ohms bridged1000 W
Signal to Noise Ratio> 100 dB
Voltage Gain32 dB
Input Impedance10 kΩ
Frequency Response20 Hz - 20 kHz

Summary

Power Supply Service and Safety

High Voltage Safety Precautions

Critical safety warning regarding high voltage levels and line potential.

Power Supply Measurement Guidelines

General guidelines for performing service and measurements on the power supply unit.

SS 1300 Power Supply Troubleshooting

Required Measurement Equipment for Power Supply

List of necessary tools and equipment for power supply servicing.

Initial Power Supply Setup and Voltage Adjustment

Procedures for initial setup, variac adjustment, and voltage checks.

Oscilloscope Diagnostics for Power Supply Faults

Using an oscilloscope for checks and diagnosing faults like spikes or distortion.

SS 1300 Output Circuit Service Procedures

Identifying Faulty Output Channels

Procedures to identify and isolate broken output channels by checking fuses.

Output Transistor Testing and Verification

Steps for testing, replacing, and verifying output transistors and associated circuits.

Sinewave Input and Output Circuit Verification

Verifying output performance and stability using a sinewave source.

Driver Circuit and DC Voltage Servicing

Driver Circuit Diagnostics and Servicing

Procedures for diagnosing and servicing the driver circuits.

DC Voltage Checks for Troubleshooting

Measurements of DC voltages at various points for diagnostics.