Operating Instructions for pressure transmitter
PASCAL CS
, Type Series CS2100 and CS2110
Do you have questions about this device? Call our hotline at: +49 (0) 4408 804-444
LABOM Mess- und Regeltechnik GmbH · Im Gewerbepark 13 · 27798 Hude · Germany
Tel.: +49 (0) 4408 804-0 · Fax: +49 (0) 4408 804-100 · e-mail: info@labom.com · www.labom.com
BTA 060
Rev 1K1
Page 1/18
Table of contents
1 General Information ..................................................................................................... 2
1.1 Intended Use ........................................................................................................ 2
1.2 General Safety Notes............................................................................................ 2
1.3 CE Marking........................................................................................................... 2
2 Transportation and Storage ......................................................................................... 2
3 Installation and Commissioning ................................................................................... 2
3.1 Electrical Connection ............................................................................................ 3
3.2 Adjusting the display unit ...................................................................................... 4
3.3 Devices with flush mounted diaphragm ................................................................ 4
4 Operation..................................................................................................................... 5
4.1 Setup / Parameterization ...................................................................................... 5
4.2 Maintenance ......................................................................................................... 5
5 Removal....................................................................................................................... 5
6 User Manual................................................................................................................. 6
6.1 System operating principles.................................................................................. 6
6.2 Main menu.......................................................................................................... 10
6.3 Basic menu (bASE)............................................................................................. 10
6.4 Display menu (diSP).......................................................................................... 13
6.5 Switch-point menu .............................................................................................. 14
6.6 System menu...................................................................................................... 17
6.7 Overview of the menu tree.................................................................................. 18
Question and Answer IconNeed help?

Do you have a question about the Labom PASCAL CS and is the answer not in the manual?

Labom PASCAL CS Specifications

General IconGeneral
TypePressure Transmitter
Measuring principlePiezoresistive
Housing materialStainless steel
Output signal4-20 mA, HART
Process connectionG 1/2
Power supplyDC 10 ... 36 V
Electrical connectionM12, Cable gland
Protection classIP65
Ambient temperature range-40 ... +85 °C
Process temperature range-20...125 °C
MaterialStainless steel
Accuracy≤ ±0.1 %